Quantification of cyclosporine and tacrolimus in whole blood. Comparison of liquid chromatography-electrospray mass spectrometry with the enzyme multiplied immunoassay technique

被引:49
作者
Ansermot, Nicolas
Fathi, Marc
Veuthey, Jean-Luc [2 ]
Desmeules, Jules
Rudaz, Serge [2 ]
Hochstrasser, Denis [1 ,2 ]
机构
[1] Univ Hosp Geneva, Lab Med Serv, Div Clin Pharmacol & Toxicol, CH-1211 Geneva 14, Switzerland
[2] Univ Lausanne, Univ Geneva, Sch Pharmaceut Sci, Lab Analyt Pharmaceut Chem, Geneva, Switzerland
关键词
immunosuppressants; LC-MS; EMIT; method comparison; Passing-Bablok; Bland-Altman;
D O I
10.1016/j.clinbiochem.2008.02.015
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 [基础医学];
摘要
Objectives: The aim of this work was to compare a validated liquid chromatography-mass spectrometry (LC-MS) method with the commercial enzyme multiplied immunoassay technique (EMIT) for cyclosporine and tacrolimus whole blood quantification. Design and methods: Samples of transplant patients receiving cyclosporine (n=38) or tacrolimus (n=41) were analyzed successively by LC-MS and EMIT. Several statistical approaches for method comparison were evaluated and Passing-Bablok and Bland-Altman analyses chosen. Results: Overestimations of the concentrations measured with EMIT compared to LC-MS were observed with means of 23% (range: 6% to 46%) for cyclosporine and 30% (range: -3% to 73%) for tacrolimus. Conclusion: The EMIT demonstrated significant positive biases due to cross-reactions with metabolites. This indicates that, in some clinical situations, a selective method such as LC-MS is preferable for therapeutic drug monitoring in transplant patients. (C) 2008 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:910 / 913
页数:4
相关论文
共 33 条
[1]
Cyclosporin: revisions in monitoring guidelines and review of current analytical methods [J].
Andrews, D ;
Cramb, R .
ANNALS OF CLINICAL BIOCHEMISTRY, 2002, 39 :424-435
[2]
Simultaneous quantification of cyclosporine, tacrolimus, sirolimus and everolimus in whole blood by liquid chromatography - electrospray mass spectrometry [J].
Ansermot, Nicolas ;
Fathi, Marc ;
Veuthey, Jean-Luc ;
Desmeules, Jules ;
Rudaz, Serge ;
Hochstrasser, Denis .
CLINICAL BIOCHEMISTRY, 2008, 41 (09) :728-735
[3]
COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[4]
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]
BLECK JS, 1991, EUR J CLIN PHARMACOL, V40, P565
[6]
Application of the EMIT 2000 Tacrolimus assay on the Abbott Architect c8000 high volume clinical chemistry analyzer [J].
Boer, Klas ;
Deufel, Thomas ;
Schmidt, Dirk ;
Streck, Sibylle ;
Kiehntopf, Michael .
CLINICAL BIOCHEMISTRY, 2006, 39 (10) :1041-1043
[7]
Comparison of different cyclosporine immunoassays to monitor C0 and C2 blood levels from kidney transplant recipients:: Not simply overestimation [J].
Cattaneo, D ;
Zenoni, S ;
Murgia, B ;
Merlini, S ;
Baldelli, S ;
Perico, N ;
Gotti, E ;
Ottomano, C ;
Crippa, A ;
Remuzzi, G .
CLINICA CHIMICA ACTA, 2005, 355 (1-2) :153-164
[8]
Dewitte K, 2002, CLIN CHEM, V48, P799
[9]
Cyclosporin -: An updated review of the pharmacokinetic properties, clinical efficacy and tolerability of a microemulsion-based formulation (Neoral®)1 in organ transplantation [J].
Dunn, CJ ;
Wagstaff, AJ ;
Perry, CM ;
Plosker, GL ;
Goa, KL .
DRUGS, 2001, 61 (13) :1957-2016
[10]
Gonschior AK, 1996, CLIN CHEM, V42, P1426