Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants

被引:317
作者
Williams, Justin C. [1 ]
Hippensteel, Joseph A. [1 ]
Dilgen, John [2 ]
Shain, William [2 ]
Kipke, Daryl R. [3 ]
机构
[1] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53706 USA
[2] Wadsworth Ctr, New York, NY USA
[3] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
关键词
D O I
10.1088/1741-2560/4/4/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A series of animal experiments was conducted to characterize changes in the complex impedance of chronically implanted electrodes in neural tissue. Consistent trends in impedance changes were observed across all animals, characterized as a general increase in the measured impedance magnitude at 1 kHz. Impedance changes reach a peak approximately 7 days post-implant. Reactive responses around individual electrodes were described using immuno-and histo-chemistry and confocal microscopy. These observations were compared to measured impedance changes. Several features of impedance changes were able to differentiate between confined and extensive histological reactions. In general, impedance magnitude at I kHz was significantly increased in extensive reactions, starting about 4 days post-implant. Electrodes with extensive reactions also displayed impedance spectra with a characteristic change at high frequencies. This change was manifested in the formation of a semi-circular arc in the Nyquist space, suggestive of increased cellular density in close proximity to the electrode site. These results suggest that changes in impedance spectra are directly influenced by cellular distributions around implanted electrodes over time and that impedance measurements may provide an online assessment of cellular reactions to implanted devices.
引用
收藏
页码:410 / 423
页数:14
相关论文
共 44 条
[1]   HISTOPATHOLOGIC EVALUATION OF PROLONGED INTRACORTICAL ELECTRICAL-STIMULATION [J].
AGNEW, WF ;
YUEN, TGH ;
MCCREERY, DB ;
BULLARA, LA .
EXPERIMENTAL NEUROLOGY, 1986, 92 (01) :162-185
[2]  
Amat JA, 1996, GLIA, V16, P368, DOI 10.1002/(SICI)1098-1136(199604)16:4<368::AID-GLIA9>3.0.CO
[3]  
2-W
[4]  
Brett M.A., 1993, ELECTROCHEMISTRY PRI
[5]   Measurement of sealing resistance of cell-electrode interfaces in neuronal cultures using impedance spectroscopy [J].
Buitenweg, JR ;
Rutten, WLC ;
Willems, WPA ;
van Nieuwkasteele, JW .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (05) :630-637
[6]  
BURNS BD, 1974, ELECTROEN CLIN NEURO, V36, P314
[7]   Monitoring cellular edema at single-neuron level by electrical resistance measurements [J].
Demirci, M ;
Ayata, C ;
Dalkara, T ;
Erdemli, G ;
Onur, R .
JOURNAL OF NEUROSCIENCE METHODS, 1997, 72 (02) :175-181
[8]   FACTORS INFLUENCING THE BIOCOMPATIBILITY OF INSERTABLE SILICON MICROSHAFTS IN CEREBRAL-CORTEX [J].
EDELL, DJ ;
TOI, VV ;
MCNEIL, VM ;
CLARK, LD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (06) :635-643
[9]   Monitoring of cellular behaviour by impedance measurements on interdigitated electrode structures [J].
Ehret, R ;
Baumann, W ;
Brischwein, M ;
Schwinde, A ;
Stegbauer, K ;
Wolf, B .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (01) :29-41
[10]   Three-dimensional hydrogel cultures for modeling changes in tissue impedance around microfabricated neural probes [J].
Frampton, J. P. ;
Hynd, M. R. ;
Williams, J. C. ;
Shuler, M. L. ;
Shain, W. .
JOURNAL OF NEURAL ENGINEERING, 2007, 4 (04) :399-409