The use of carbon marking after stereotactic large-core-needle breast biopsy

被引:22
作者
Mullen, DJ
Eisen, RN
Newman, RD
Perrone, PM
Wilsey, JC
机构
[1] Greenwich Hosp, Dept Radiol, Greenwich, CT 06830 USA
[2] Greenwich Hosp, Dept Pathol, Greenwich, CT 06830 USA
[3] Greenwich Hosp, Dept Surg, Greenwich, CT 06830 USA
关键词
biopsies; technology; breast; biopsy; breast neoplasms; diagnosis; stereotaxis;
D O I
10.1148/radiology.218.1.r01ja33255
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To investigate the use of activated charcoal to mark the biopsy site and needle track after large-core-needle breast biopsy. MATERIALS AND METHODS: Three hundred seventy-six consecutive patients (with 383 lesions) were referred for stereotactic breast biopsy. Two hundred forty seven lesions were carbon marked when the need for surgery was likely. Patients who underwent marking were followed up for the results of surgery or mammography performed at our institution. Specimen sizes obtained by using the carbon mark were compared with sizes of consecutive biopsy specimens obtained after hook-wire localization. RESULTS: Carbon marking was well tolerated in all cases. All 132 surgeries performed at the authors' institution were successful in removing the marked target. Specimen sizes compared favorably with sizes of comparison hook-wire localization specimens. All 68 lesions followed mammographically revealed no changes that were attributable to the use of carbon. Two minor complications were observed. Two small cancers were completely removed at needle biopsy. CONCLUSION: Carbon marking is safe and effective for marking the biopsy site and needle track created by stereotactic large-core-needle biopsy of the breast. Marking eliminates the need for postprocedural needle localization. It remains effective when small lesions have been completely removed. This technique should be considered in properly selected cases by those performing large-core-needle biopsy of the breast.
引用
收藏
页码:255 / 260
页数:6
相关论文
共 36 条
[1]   STEREOTACTIC FINE-NEEDLE BIOPSY IN 2594 MAMMOGRAPHICALLY DETECTED NON-PALPABLE LESIONS [J].
AZAVEDO, E ;
SVANE, G ;
AUER, G .
LANCET, 1989, 1 (8646) :1033-1036
[2]   INDOCYANINE GREEN-DYE AS A TISSUE MARKER FOR LOCALIZATION OF NONPALPABLE BREAST-LESIONS [J].
BERRIDGE, DL ;
MASTEY, LA ;
ECKSTROM, PC ;
CZARNECKI, DJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (05) :1299-1299
[3]   Lesions entirely removed during stereotactic biopsy: Preoperative localization on the basis of mammographic landmarks and feasibility of freehand technique-initial experience [J].
Brenner, RJ .
RADIOLOGY, 2000, 214 (02) :585-590
[4]   TRANSGRESSION OF LOCALIZING WIRE INTO THE PLEURAL CAVITY PRIOR TO MAMMOGRAPHY [J].
BRISTOL, JB ;
JONES, PA .
BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (638) :139-140
[5]   Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with directional, vacuum-assisted biopsy [J].
Burbank, F .
RADIOLOGY, 1997, 202 (03) :843-847
[6]   Tissue marking clip for stereotactic breast biopsy: Initial placement accuracy, long-term stability, and usefulness as a guide for wire localization [J].
Burbank, F ;
Forcier, N .
RADIOLOGY, 1997, 205 (02) :407-415
[7]  
Burbank F, 1996, AM SURGEON, V62, P128
[8]  
Canavese G, 1995, Eur J Surg Oncol, V21, P47, DOI 10.1016/S0748-7983(05)80067-8
[9]   MIGRATION OF BREAST BIOPSY LOCALIZATION WIRE [J].
DAVIS, PS ;
WECHSLER, RJ ;
FEIG, SA ;
MARCH, DE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (04) :787-788
[10]  
DELPORTE P, 1994, J CHIR-PARIS, V131, P549