Improving mammographic interpretation: Double reading and computer-aided diagnosis

被引:15
作者
Helvie, Mark [1 ]
机构
[1] Univ Michigan Hlth Syst, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
D O I
10.1016/j.rcl.2007.06.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This article discusses two commonly used techniques advocated to improve screening mammography performance: double reading (DR) and computer-aided detection (CAD). Analysis of these methods is incomplete because no randomized controlled trials have been performed to assess changes in survival. Although DR and CAD have shown improvement in sensitivity, specificity often has decreased. Balancing which parameter is more important involves health care policy, costs, cultural factors, legal risk, and patient preference.
引用
收藏
页码:801 / +
页数:12
相关论文
共 46 条
[1]   Use of computer-aided detection (CAD) tools in screening mammography: a multidisciplinary investigation [J].
Alberdi, E ;
Povyakalo, AA ;
Strigini, L ;
Ayton, P ;
Hartswood, M ;
Procter, R ;
Slack, R .
BRITISH JOURNAL OF RADIOLOGY, 2005, 78 :S31-S40
[2]   Effects of incorrect computer-aided detection (CAD) output on human decision-making in mammography [J].
Alberdi, E ;
Povyakalo, A ;
Strigini, L ;
Ayton, P .
ACADEMIC RADIOLOGY, 2004, 11 (08) :909-918
[3]   THE EFFICACY OF DOUBLE READING MAMMOGRAMS IN BREAST SCREENING [J].
ANDERSON, EDC ;
MUIR, BB ;
WALSH, JS ;
KIRKPATRICK, AE .
CLINICAL RADIOLOGY, 1994, 49 (04) :248-251
[4]   DOUBLE READING OF MAMMOGRAPHY SCREENING FILMS - ONE RADIOLOGIST OR 2 [J].
ANTTINEN, I ;
PAMILO, M ;
SOIVA, M ;
ROIHA, M .
CLINICAL RADIOLOGY, 1993, 48 (06) :414-421
[5]   Evaluation of proscriptive health care policy implementation in screening mammography [J].
Beam, CA ;
Conant, EF ;
Sickles, EA ;
Weinstein, SP .
RADIOLOGY, 2003, 229 (02) :534-540
[6]   Association of volume and volume-independent factors with accuracy in screening mammogram interpretation [J].
Beam, CA ;
Conant, EF ;
Sickles, EA .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2003, 95 (04) :282-290
[7]   Effect of human variability on independent double: Reading in screening mammography [J].
Beam, CA ;
Sullivan, DC ;
Layde, PM .
ACADEMIC RADIOLOGY, 1996, 3 (11) :891-897
[8]   Reader strategies: Variability and error- methodology, findings and health policy implications from a study of the US population of mammographers [J].
Beam, CA .
MEDICAL IMAGING 2002: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2002, 4686 :157-168
[9]   Computer-aided detection with screening mammography in a university hospital setting [J].
Birdwell, RL ;
Bandodkar, P ;
Ikeda, DM .
RADIOLOGY, 2005, 236 (02) :451-457
[10]   Improvement in sensitivity of screening mammography with computer-aided detection: A multiinstitutional trial [J].
Brem, RF ;
Baum, J ;
Lechner, M ;
Kaplan, S ;
Souders, S ;
Naul, LG ;
Hoffmeister, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (03) :687-693