摘要
Purpose: To implement and evaluate the accuracy of non-invasive temperature mapping using MRI methods based on the chemical shift (CS) and T-1 relaxation in media of various heterogeneity during focal (laser) and external thermal energy deposition. Materials and Methods: All measurements mere performed on a 1.5 T superconducting clinical scanner using the temperature dependence of the water proton chemical shift and the T-1 relaxation time, Homogeneous gel and heterogeneous muscle phantoms were heated focally with a fiberoptic laser probe and externally of varying degree ex vivo by water circulating in a temperature range of 20-50 degrees C. Magnetic resonance imaging data were compared to simultaneously recorded fiberoptic temperature readings. Results: Both methods provided accurate results in homogeneous media (turkey) with better accuracy for the chemical shift method (CS: +/-1.5 degrees C, T-1: +/-2.0 degrees C:). Ln gel, the accuracy with the CS method was +/-0.6 degrees C. The accuracy decreased in heterogeneous media containing fat (T-1: +/-3.5 degrees C, CS: +5 degrees C). In focal heating of turkey muscle, the accuracy was within 1.5 degrees C with the T-1 method. Conclusion: Temperature monitoring with the chemical shift provides better results in homogeneous media containing no fat, In fat tissue, the temperature calculation proved to be difficult. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:393 / 403
页数:11
相关论文
共 40 条
[1]   A new ytterbium chelate as contrast agent in chemical shift imaging and temperature sensitive probe for MR spectroscopy [J].
Aime, S ;
Botta, M ;
Fasano, M ;
Terreno, E ;
Kinchesh, P ;
Calabi, L ;
Paleari, L .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :648-651
[2]   BLOOD-FLOW EFFECTS IN MAGNETIC-RESONANCE IMAGING [J].
AXEL, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1157-1166
[3]   RELAXATION EFFECTS IN NUCLEAR MAGNETIC RESONANCE ABSORPTION [J].
BLOEMBERGEN, N ;
PURCELL, EM ;
POUND, RV .
PHYSICAL REVIEW, 1948, 73 (07) :679-712
[4]   FAST AND PRECISE T1 IMAGING USING A TOMROP SEQUENCE [J].
BRIX, G ;
SCHAD, LR ;
DEIMLING, M ;
LORENZ, WJ .
MAGNETIC RESONANCE IMAGING, 1990, 8 (04) :351-356
[5]   NONINVASIVE TEMPERATURE IMAGING USING DIFFUSION MRI [J].
DELANNOY, J ;
CHEN, CN ;
TURNER, R ;
LEVIN, RL ;
LEBIHAN, D .
MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) :333-339
[6]   THE PROTON-RESONANCE-FREQUENCY-SHIFT METHOD COMPARED WITH MOLECULAR-DIFFUSION FOR QUANTITATIVE MEASUREMENT OF 2-DIMENSIONAL TIME-DEPENDENT TEMPERATURE DISTRIBUTION IN A PHANTOM [J].
DEPOORTER, J ;
DEWAGTER, C ;
DEDEENE, Y ;
THOMSEN, C ;
STAHLBERG, F ;
ACHTEN, E .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03) :234-241
[7]  
DEPOORTER J, 1995, MAGN RESON MED, V34, P359, DOI 10.1002/mrm.1910340313
[8]  
DEPOORTER J, 1995, MAGNET RESON MED, V33, P74, DOI 10.1002/mrm.1910330111
[9]  
Ernst R. R., 1987, PRINCIPLES NUCL MAGN
[10]   OBSERVATION OF PERSISTENT CURRENT IN A SUPERCONDUCTING SOLENOID [J].
FILE, J ;
MILLS, RG .
PHYSICAL REVIEW LETTERS, 1963, 10 (03) :93-&