The effect of using transverse fins on a double pass flow solar air heater using wire mesh as an absorber

被引:107
作者
El-khawajah, M. F. [1 ]
Aldabbagh, L. B. Y. [1 ]
Egelioglu, F. [1 ]
机构
[1] Eastern Mediterranean Univ, Dept Mech Engn, Gazimagusa 10, Mersin, Turkey
关键词
Counter flow solar air heater (SAH); Wire mesh; Fins; Thermal efficiency; THERMAL PERFORMANCE; COLLECTOR; EFFICIENCY; ENERGY;
D O I
10.1016/j.solener.2011.04.004
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
080707 [能源环境工程]; 082001 [油气井工程];
摘要
The thermal performance of a double pass solar air heater with 2, 4, and 6 fins attached was investigated experimentally. Wire mesh layers were used between the fins instead of an absorber plate. The effects of mass flow rate of air on the outlet temperature and thermal efficiency were studied. The indicated results show that the efficiency increases with increasing the mass flow rate for the range of the flow rate used in this work between 0.0121-0.042 kg/s. Moreover, the maximum efficiency was obtained by using 6 fins at the same mass flow rate. The maximum efficiency obtained for the 2, 4, 6 fins of SAH were 75.0%, 82.1% and 85.9% respectively for the mass flow rate of 0.042 kg/s. In addition, the maximum average temperature difference between the inlet and the outlet, Delta T, for the SAH with 6 fins was the highest for the same mass flow rates compared to 2 and 4 fins SAHs. The maximum average and instantaneous peak of Delta T obtained were 43.1 degrees C and 62.1 degrees C respectively for the 6 fins SAH when the mass flow rate was 0.0121 kg/s. Comparison of the results of a counter flow packed bed collector with those of a conventional collector shows a substantial enhancement in the thermal efficiency. Published by Elsevier Ltd.
引用
收藏
页码:1479 / 1487
页数:9
相关论文
共 27 条
[1]
Mathematical modelling of a thin layer drying of apricots in a solar energized rotary dryer [J].
Akpinar, EK ;
Sarsilmaz, C ;
Yildiz, C .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2004, 28 (08) :739-752
[2]
AKPINAR EK, 2010, HEAT MASS TRANSFER, V37, P416
[3]
Single and double pass solar air heaters with wire mesh as packing bed [J].
Aldabbagh, L. B. Y. ;
Egelioglu, F. ;
Ilkan, M. .
ENERGY, 2010, 35 (09) :3783-3787
[4]
ALDABBAGH LBY, 2010, 7 INT C HEAT TRANSF
[5]
Experimental and numerical investigation of a flat-plate solar collector [J].
Alvarez, A. ;
Cabeza, O. ;
Muniz, M. C. ;
Varela, L. M. .
ENERGY, 2010, 35 (09) :3707-3716
[6]
Year round performance of double pass solar air heater with packed bed [J].
El-Sebaii, A. A. ;
Aboul-Enein, S. ;
Ramadan, M. R. I. ;
El-Bialy, E. .
ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (03) :990-1003
[7]
Experimental energy and exergy analysis of a double-flow solar air heater having different obstacles on absorber plates [J].
Esen, Hikmet .
BUILDING AND ENVIRONMENT, 2008, 43 (06) :1046-1054
[8]
Artificial neural network and wavelet neural network approaches for modelling of a solar air heater [J].
Esen, Hikmet ;
Ozgen, Filiz ;
Esen, Mehmet ;
Sengur, Abdulkadir .
EXPERT SYSTEMS WITH APPLICATIONS, 2009, 36 (08) :11240-11248
[9]
Modelling of a new solar air heater through least-squares support vector machines [J].
Esen, Hikmet ;
Ozgen, Filiz ;
Esen, Mehmet ;
Sengur, Abdulkadir .
EXPERT SYSTEMS WITH APPLICATIONS, 2009, 36 (07) :10673-10682
[10]
Performance evaluation of solar air heater for various artificial roughness geometries based on energy, effective and exergy efficiencies [J].
Gupta, M. K. ;
Kaushik, S. C. .
RENEWABLE ENERGY, 2009, 34 (03) :465-476