Extensor mechanism function in single-radius vs multiradius femoral components for total knee arthroplasty

被引:40
作者
Hall, James [3 ]
Copp, Steven N. [2 ]
Adelson, Wendy S. [1 ]
D'Lima, Darryl D. [1 ]
Colwell, Clifford W., Jr. [1 ,2 ]
机构
[1] Scripps Clin, Shiley Ctr Orthopaed Res & Educ, La Jolla, CA 92037 USA
[2] Scripps Clin, Div Orthopaed Surg, La Jolla, CA 92037 USA
[3] Ctr Orthopaed & Neurosurg Care & Res, Bend, OR USA
关键词
total knee arthroplasty; extensor mechanism function; posterior cruciate ligament-retaining implant; multiradius implant; single sagittal radius implant;
D O I
10.1016/j.arth.2007.04.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The early outcomes of 2 newer-generation posterior cruciate ligament-retaining fixed-bearing total knee arthroplasty (TKA) implant designs were assessed to determine if a single sagittal radius femoral design has an advantage in obtaining earlier knee range of motion and function when compared with a contemporary multiradius femoral design. Total knee arthroplasty patients were prospectively randomized to receive either a single sagittal radius femoral design (n = 50) or a multiradius femoral design (n = 50). Knee extensor mechanism function after TKA with either a single sagittal radius or multiradius implant was comparable in contemporary posterior cruciate ligament-retaining TKA designs.
引用
收藏
页码:216 / 219
页数:4
相关论文
共 9 条
[1]
D'Lima DD, 2001, CLIN ORTHOP RELAT R, P213
[2]
FORCES IN THE KNEE-JOINT WHILE RISING FROM A SEATED POSITION [J].
ELLIS, MI ;
SEEDHOM, BB ;
WRIGHT, V .
JOURNAL OF BIOMEDICAL ENGINEERING, 1984, 6 (02) :113-120
[3]
THE POSTERIOR STABILIZED CONDYLAR PROSTHESIS - A MODIFICATION OF THE TOTAL CONDYLAR DESIGN - 2-YEAR TO 4-YEAR CLINICAL-EXPERIENCE [J].
INSALL, JN ;
LACHIEWICZ, PF ;
BURSTEIN, AH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (09) :1317-1323
[4]
The effect of total knee arthroplasty design on extensor mechanism function [J].
Mahoney, OM ;
McClung, CD ;
dela Rosa, MA ;
Schmalzried, TP .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :416-421
[5]
Altered loading during walking and sit-to-stand is affected by quadriceps weakness after total knee arthroplasty [J].
Mizner, RL ;
Snyder-Mackler, L .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2005, 23 (05) :1083-1090
[6]
Early quadriceps strength loss after total knee arthroplasty - The contributions of muscle atrophy and failure of voluntary muscle activation [J].
Mizner, RL ;
Petterson, SC ;
Stevens, JE ;
Vandenborne, K ;
Snyder-Mackler, L .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (05) :1047-1053
[7]
The John Insall Award - Patient expectations affect satisfaction with total knee arthroplasty [J].
Noble, Philip C. ;
Conditt, Michael A. ;
Cook, Karon F. ;
Mathis, Kenneth B. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) :35-43
[8]
RANAWAT CS, 1976, CLIN ORTHOP RELAT R, P76
[9]
Knee strength after total knee arthroplasty [J].
Silva, M ;
Shepherd, EF ;
Jackson, WO ;
Pratt, JA ;
McClung, CD ;
Schmalzried, TP .
JOURNAL OF ARTHROPLASTY, 2003, 18 (05) :605-611