This paper presents a sequential injection analysis (SIA) system for sequential monitoring of Fe(II) and Fe(III), or NO3- and NO2- with typical concentrations of natural and waste waters. Determination of nitrite was based on the Griess-Ilosvay reaction, while the Fe(II) determination was based on the reaction with 1,10-phenantroline. Determination of Fe(III) and NO3- were performed after their reduction, respectively, in Jones and copperized cadmium columns, using forward and reversal flow directions. Tangential filtration permitted the application of the methodology for determination of dissolved species in aquatic suspensions containing particulate matter and sediments. The stability of the analytical curves was verified over periods of 4-5 days. Quantification limits for NO2- and NO3- were 0.01 and 0.02 mg l(-1) N, respectively. For Fe(II) and Fe(III) the quantification limits were 0.05 and 0.1 mg l(-1), respectively, with a sampling frequency of 20 h(-1). The influence of sulphides and natural organic matter on the performance of the reducing columns were evaluated, as well as the use of regeneration solutions. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:39 / 48
页数:10
相关论文
共 23 条
[1]  
*AM PUBL HLTH ASS, 1995, STAND METH EX WAT WA
[2]  
[Anonymous], 1989, FLOW INJECTION ANAL
[3]   Sequential injection analysis: an alternative approach to process analytical chemistry [J].
Barnett, NW ;
Lenehan, CE ;
Lewis, SW .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (05) :346-353
[4]   NOVEL SINGLE STANDARD CALIBRATION AND DILUTION METHOD PERFORMED BY THE SEQUENTIAL INJECTION TECHNIQUE [J].
BARON, A ;
GUZMAN, M ;
RUZICKA, J ;
CHRISTIAN, GD .
ANALYST, 1992, 117 (12) :1839-1844
[5]   CONFIGURATION WITH INTERNALLY COUPLED VALVES TO OVERCOME SHORTCOMINGS IN THE SIMULTANEOUS DETERMINATION OF NITRITE AND NITRATE BY FLOW-INJECTION ANALYSIS [J].
BERMUDEZ, B ;
RIOS, A ;
DECASTRO, MDL ;
VALCARCEL, M .
TALANTA, 1988, 35 (10) :810-812
[6]   Sequential injection sandwich technique for the simultaneous determination of nitrate and nitrite [J].
Cerdà, A ;
Oms, MT ;
Forteza, R ;
Cerdà, V .
ANALYTICA CHIMICA ACTA, 1998, 371 (01) :63-71
[7]   Flow techniques in water analysis [J].
Cerdà, V ;
Estela, JM ;
Forteza, R ;
Cladera, A ;
Becerra, E ;
Altimira, P ;
Sitjar, P .
TALANTA, 1999, 50 (04) :695-705
[8]   COMPARISON OF THE MAXIMUM SENSITIVITY OF DIFFERENT FLOW-INJECTION MANIFOLD CONFIGURATIONS - ALTERNATING VARIABLE SEARCH OPTIMIZATION OF THE IRON(II)/1,10-PHENANTHROLINE SYSTEM [J].
CHALK, SJ ;
TYSON, JF .
ANALYTICAL CHEMISTRY, 1994, 66 (05) :660-666
[9]   A STUDY OF IRON AND MANGANESE TRANSFORMATIONS AT THE O2/S(-II) TRANSITION LAYER IN A EUTROPHIC LAKE (LAKE BRET, SWITZERLAND) - A MULTIMETHOD APPROACH [J].
DEVITRE, RR ;
BUFFLE, J ;
PERRET, D ;
BAUDAT, R .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1988, 52 (06) :1601-1613
[10]   APPLICATION OF A REDUCING COLUMN FOR METAL SPECIATION BY FLOW-INJECTION ANALYSIS - SPECTROPHOTOMETRIC DETERMINATION OF IRON(III) AND SIMULTANEOUS DETERMINATION OF IRON(II) AND TOTAL IRON [J].
FAIZULLAH, AT ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1985, 167 (JAN) :225-231