Optimization of headspace solid-phase microextraction conditions for the determination of organophosphorus insecticides in natural waters

被引:122
作者
Lambropoulou, DA [1 ]
Albanis, TA [1 ]
机构
[1] Univ Ioannina, Dept Chem, Lab Ind Chem, GR-45110 Ioannina, Greece
关键词
headspace analysis; solid-phase microextraction; water analysis; environmental analysis; flame thermionic detection; pesticides; organophosphorus compounds;
D O I
10.1016/S0021-9673(01)00953-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Headspace solid-phase microextraction (HS-SPME) has been developed for the analysis of seven organophosphorus insecticides, i.e. diazinon, fenitrothion, fenthion, ethyl parathion, methyl bromophos, ethyl bromophos and ethion in natural waters. Their determination was carried out using gas chromatography with flame thermionic and mass spectrometric detection. To perform the HS-SPME, two types of fibre have been assayed and compared: polyacrylate (PA 85 mum), and polydimethylsiloxane (PDMS 100 mum). The main parameters, affecting the HS-SPME process such as temperature, salt additives, memory effect, stirring rate and adsorption-time profile were studied. The method was developed using spiked natural waters such as ground, sea, river and lake water in a concentration range of 0.05-1 mug/l. The HS-SPME conditions were optimized in order to obtain the maximum sensitivity. Detection limits varied from 0.01 to 0.04 mug/l and relative standard deviations (RSD < 17%) were obtained showing that the precision of the method is reliable. The method showed also good linearity for the tested concentration range with regression coefficients ranging between 0.985 and 0.999. Recoveries were in relatively high levels for all the analytes and ranged from 80 to 120%. Water samples collected from different stations along the flow of Kalamas river (NW Greece) were analyzed using the optimized conditions in order to evaluate the potential of the proposed method to the trace-level screening determination of organophosphorus insecticides. The analysis with HS-SPME has less background interference and the advantage of its non-destructive nature reveal the possibility of the repetitive use of the SPME fibre. (C) 2001 Elsevier Science BN. All rights reserved.
引用
收藏
页码:243 / 255
页数:13
相关论文
共 34 条
[1]   Solid phase microextraction for quantitative analysis in nonequilibrium situations [J].
Ai, J .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1230-1236
[2]   USE OF EXTRACTION DISKS FOR TRACE ENRICHMENT OF VARIOUS PESTICIDES FROM RIVER WATER AND SIMULATED SEAWATER SAMPLES FOLLOWED BY LIQUID-CHROMATOGRAPHY RAPID-SCANNING UV VISIBLE AND THERMOSPRAY MASS-SPECTROMETRY DETECTION [J].
BARCELO, D ;
DURAND, G ;
BOUVOT, V ;
NIELEN, M .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (02) :271-277
[3]   Solid-phase microextraction for quantitative analysis of organophosphorus pesticides in environmental water samples [J].
Beltran, J ;
Lopez, FJ ;
Cepria, O ;
Hernandez, F .
JOURNAL OF CHROMATOGRAPHY A, 1998, 808 (1-2) :257-263
[4]   Solid-phase microextraction in pesticide residue analysis [J].
Beltran, J ;
López, FJ ;
Hernández, F .
JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) :389-404
[5]   SOLID-PHASE MICROEXTRACTION OF NITROGEN-CONTAINING HERBICIDES [J].
BOYDBOLAND, AA ;
PAWLISZYN, JB .
JOURNAL OF CHROMATOGRAPHY A, 1995, 704 (01) :163-172
[6]   Monitoring organochlorine pesticides from landfill leachates by gas chromatography-electron-capture detection after solid-phase microextraction [J].
Brás, I ;
Santos, L ;
Alves, A .
JOURNAL OF CHROMATOGRAPHY A, 2000, 891 (02) :305-311
[7]   Solid-phase microextraction of nitrogen and phosphorus-containing pesticides from water and gas chromatographic analysis [J].
Choudhury, TK ;
Gerhardt, KO ;
Mawhinney, TP .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1996, 30 (11) :3259-3265
[8]  
COLINA C, 1993, J CHROMATOGR A, V655, P127
[9]   DETERMINATION OF CARBARYL AND SOME ORGANOPHOSPHORUS PESTICIDES IN DRINKING-WATER USING ONLINE LIQUID-CHROMATOGRAPHIC PRECONCENTRATION TECHNIQUES [J].
DRISS, MR ;
HENNION, MC ;
BOUGUERRA, ML .
JOURNAL OF CHROMATOGRAPHY, 1993, 639 (02) :352-358
[10]   Effect of the various parameters governing solid-phase microextraction for the trace-determination of pesticides in water [J].
Dugay, J ;
Miège, C ;
Hennion, MC .
JOURNAL OF CHROMATOGRAPHY A, 1998, 795 (01) :27-42