Hypersensitivity pneumonitis in a metal-working environment

被引:60
作者
Hodgson, MJ
Bracker, A
Yang, C
Storey, E
Jarvis, BJ
Milton, D
Lummus, Z
Bernstein, D
Cole, S
机构
[1] Vet Hlth Adm, Occupat Hlth Programs 136, Washington, DC 20420 USA
[2] Univ Connecticut, Ctr Hlth, Div Environm & Occupat Med, Farmington, CT USA
[3] P&K Microbiol, Cherry Hill, NJ USA
[4] Univ Maryland, Dept Chem & Biochem, College Pk, MD 20742 USA
[5] Harvard Univ, Sch Publ Hlth, Boston, MA 02115 USA
[6] Univ Cincinnati, Dept Internal Med, Div Immunol, Cincinnati, OH USA
[7] Hartford Hosp, Dept Pathol, Hartford, CT 06115 USA
关键词
hypersensitivity pneumonitis; metal-working fluids; questionnaires; screening; surveillance;
D O I
10.1002/ajim.1061
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background An outbreak of lung disease among workers lit a metal-working plant included 16 biopsy-confirmed cases of hypersensitivity pneumonitis and additional patients with asthma, bronchiolitis and emphysema, usual interstitial pneumonitis, and sarcoidosis. Study design Clinical examination of patients; cross-sectional questionnaire survey of the outbreak plant and two control plant areas, one with and one without MWF exposures, in a separate facility; industrial hygiene survey with laboratory characterization of microbial flora; and immunological investigation Methods Patients with suspected hypersensitivity pneumonitis underwent a clinical examination including detailed lung function, imaging, and tissue studies. A plant walk through identified metal-working processes, microbial aerosols, and work practices. Microbial characteristics of the three microbial aerosol-producing precesses were characterized. Antibodies to those agents were determined in patient sera. A questionnaire survey was conducted in the case plant and irt two areas of a control plant one with and one without metal-working fluids exposure. Results Thirty-nine (79.6%) patients described symptoms consistent with work-related lung disease, eight received other diagnoses, and two did not complete their examinations. Sixteen patients had hypersensitivity pneumonitis confirmed on biopsy. Mean decrements in lung forced expiratory volume in 1 s and force vital capacity from before to after work were similar in the 16 biopsy-confirmed cases of hypersensitivity pneumonitis (-6.3%; -7.2%) and the 19 symptomatic patients without biopsies (-11.2%, -10.1%). Symptoms were more common in rite case plant than in a non-MWF control plant area. Three sources of water-based aerosols were identified that grew similar microbial flora. Although machining increased airborne bacterial levels, the increase was not related to the concentration of viable bacteria in the sumps. Antibody testing did not identify a specific single organisms. Endotoxin levels were similar in case and MWF control plant. Conclusion Lung disease in environments with water-based aerosols may be more common than usually recognized. Patients with HP often present with only subtle abnormalities and may be missed if multiple clinical abnormalities are required to document disease. Am. J. Ind. Med. 39:616-628, 2001. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:616 / 628
页数:13
相关论文
共 60 条
[41]  
ROSE C, 1996, MMWR-MORBID MORTAL W, V45, P606
[42]   Lifeguard lung: Endemic granulomatous pneumonitis in an indoor swimming pool [J].
Rose, CS ;
Martyny, JW ;
Newman, LS ;
Milton, DK ;
King, TE ;
Beebe, JL ;
McCammon, JB ;
Hoffman, RE ;
Kreiss, K .
AMERICAN JOURNAL OF PUBLIC HEALTH, 1998, 88 (12) :1795-1800
[43]  
Rosenman KD, 1997, AM J IND MED, V32, P325, DOI 10.1002/(SICI)1097-0274(199710)32:4<325::AID-AJIM1>3.0.CO
[44]  
2-T
[45]  
ROSSMOORE HW, 1981, J OCCUP ENVIRON MED, V23, P247
[46]   SENTINEL HEALTH EVENTS (OCCUPATIONAL) - A BASIS FOR PHYSICIAN RECOGNITION AND PUBLIC-HEALTH SURVEILLANCE [J].
RUTSTEIN, DD ;
MULLAN, RJ ;
FRAZIER, TM ;
HALPERIN, WE ;
MELIUS, JM ;
SESTITO, JP .
AMERICAN JOURNAL OF PUBLIC HEALTH, 1983, 73 (09) :1054-1062
[47]   LONGITUDINAL PULMONARY-FUNCTION CHANGES IN PIGEON-BREEDERS [J].
SCHMIDT, CD ;
JENSEN, RL ;
CHRISTENSEN, LT ;
CRAPO, RO ;
DAVIS, JJ .
CHEST, 1988, 93 (02) :359-363
[48]   WHAT CAUSES CRYPTOGENIC FIBROSING ALVEOLITIS - A CASE-CONTROL STUDY OF ENVIRONMENTAL EXPOSURE TO DUST [J].
SCOTT, J ;
JOHNSTON, I ;
BRITTON, J .
BRITISH MEDICAL JOURNAL, 1990, 301 (6759) :1015-1017
[49]  
Sieber W., 1996, APPL OCCUP ENVIRON H, V11, P1387
[50]  
Sprince NL, 1997, AM J IND MED, V31, P403, DOI 10.1002/(SICI)1097-0274(199704)31:4<403::AID-AJIM5>3.0.CO