Velocity distribution and shear rate variability resulting from changes in the impeller location in the USP dissolution testing apparatus II

被引:35
作者
Bai, Ge [1 ]
Armenante, Piero M. [1 ]
机构
[1] New Jersey Inst Technol, Otto H York Dept Chem Engn, Newark, NJ 07102 USA
关键词
CFD; computational fluid dynamics; hydrodynamics; off-center impeller; USP dissolution testing apparatus;
D O I
10.1007/s11095-007-9477-z
中图分类号
O6 [化学];
学科分类号
0703 [化学];
摘要
Purpose. The United States Pharmacopoeia (USP) imposes strict requirements on the geometry and operating conditions of the USP Dissolution Testing Apparatus II. A previously validated Computational Fluid Dynamics (CFD) approach was used here to study the hydrodynamics of USP Apparatus II when the impeller was placed at four different locations, all within the limits specified by USP. Method. CFD was used to predict the velocity profiles, energy dissipation rates, and strain rates when the impeller was placed in the reference location (centrally mounted, 25 mm off the vessel bottom), 2 mm off-center, 2 mm higher, and 2 mm lower than the reference location. Results. Small changes in impeller location, especially if associated with loss of symmetry, produced extensive changes in velocity profiles and shear rates. Centrally located impellers, irrespective of their off-bottom clearance, produced non-uniform but nearly symmetric strain rates. The off-center impeller produced a more uniform but slightly asymmetric strain rate distribution. Conclusions. The system hydrodynamics depends strongly on small differences in equipment configurations and operating conditions, which are likely to affect significantly the flow field and shear rate experienced by the oral dosage form being tested, and hence the solid-liquid mass transfer and dissolution rate.
引用
收藏
页码:320 / 336
页数:17
相关论文
共 25 条
[1]
Effect of low off-bottom impeller clearance on the minimum agitation speed for complete suspension of solids in stirred tanks [J].
Armenante, PM ;
Nagamine, EU .
CHEMICAL ENGINEERING SCIENCE, 1998, 53 (09) :1757-1775
[2]
MASS-TRANSFER TO MICROPARTICLES IN AGITATED SYSTEMS [J].
ARMENANTE, PM ;
KIRWAN, DJ .
CHEMICAL ENGINEERING SCIENCE, 1989, 44 (12) :2781-2796
[3]
Experimental and computational determination of blend time in USP dissolution testing apparatus II [J].
Bai, Ge ;
Armenante, Piero M. ;
Plank, Russell V. .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2007, 96 (11) :3072-3086
[4]
Hydrodynamic investigation of USP dissolution test apparatus II [J].
Bai, Ge ;
Armenante, Piero M. ;
Plank, Russell V. ;
Gentzler, Michael ;
Ford, Kenneth ;
Harmon, Paul .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2007, 96 (09) :2327-2349
[5]
Ballard J., 2003, Dissolution Technology, V10, P6, DOI DOI 10.14227/DTL00303P6
[6]
Hydrodynamics-induced variability in the USP apparatus II dissolution test [J].
Baxter, JL ;
Kukura, J ;
Muzzio, FJ .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2005, 292 (1-2) :17-28
[7]
Bird R B., 2002, Transportphenomena
[8]
FLUID AND PARTICLE LASER DOPPLER VELOCITY-MEASUREMENTS AND MASS-TRANSFER PREDICTIONS FOR THE USP PADDLE METHOD DISSOLUTION APPARATUS [J].
BOCANEGRA, LM ;
MORRIS, GJ ;
JUREWICZ, JT ;
MAUGER, JW .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1990, 16 (09) :1441-1464
[9]
THE DEVELOPMENT OF USP DISSOLUTION AND DRUG RELEASE STANDARDS [J].
COHEN, JL ;
HUBERT, BB ;
LEESON, LJ ;
RHODES, CT ;
ROBINSON, JR ;
ROSEMAN, TJ ;
SHEFTER, E .
PHARMACEUTICAL RESEARCH, 1990, 7 (10) :983-987
[10]
Influence of dissolution medium agitation on release profiles of sustained-release tablets [J].
Costa, P ;
Lobo, JMS .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2001, 27 (08) :811-817