Reduction of rating required for circuit breakers by employing series-connected fault current limiters

被引:19
作者
Calixte, E [1 ]
Yokomizu, Y
Shimizu, H
Matsumura, T
Fujita, H
机构
[1] Nagoya Univ, Dept Elect Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[2] Chubu Elect Power Co Inc, Midori Ku, Nagoya, Aichi 4598522, Japan
关键词
D O I
10.1049/ip-gtd:20040060
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Calculation was made to examine the reduction of the rating required for circuit breakers by using series-connected resistive and inductive fault current limiters (FCLs) under various fault locations. In the model of the inductive FCL, a capacitance C-p consisting of a coil stray capacitance and a necessary additional capacitance was taken into account. The insertion of the resistive FCL and the inductive FCL with C-p = 100 nF into the power system proved to decrease the severity of the interrupting duty so that a lower-rated circuit breaker can be used. However, the introduction of the inductive FCL with C-p = 10 nF was found to lessen the fault current, while raising the rate of rise of the recovery voltage. From the variation of the breaking condition, the limiting impedance required to allow a circuit breaker to perform a satisfactory interruption is discussed.
引用
收藏
页码:36 / 42
页数:7
相关论文
共 22 条
[1]   Analysis of a passive superconducting fault current limiter [J].
Cha, YS ;
Yang, ZJ ;
Turner, LR ;
Poeppel, RB .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1998, 8 (01) :20-25
[2]   FIELD-TEST RESULTS FOR A MULTISHOT 12.47 KV FAULT CURRENT LIMITER [J].
ENGELMAN, N ;
SCHREURS, E ;
DRUGGE, B .
IEEE TRANSACTIONS ON POWER DELIVERY, 1991, 6 (03) :1081-1087
[3]  
GARZON RD, 1997, HIGH VOLTAGE CIRCUIT, P166
[4]  
Goto Y., 1999, Transactions of the Institute of Electrical Engineers of Japan, Part B, V119-B, P1241
[5]  
GUO Y, 2000, T IEE JAPAN, V120, P741
[6]   DEVELOPMENT OF A NEW 6.6KV/1500A CLASS SUPERCONDUCTING FAULT CURRENT LIMITER FOR ELECTRIC-POWER SYSTEMS [J].
HARA, T ;
OKUMA, T ;
YAMAMOTO, T ;
ITO, D ;
TASAKI, K ;
TSURUNAGA, K ;
DICK, EP .
IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (01) :182-192
[7]   A MICROPROCESSOR-CONTROLLED VARIABLE IMPEDANCE ADAPTIVE FAULT CURRENT LIMITER [J].
KING, EF ;
CHIKHANI, AY ;
HACKAM, R ;
SALAMA, MMA .
IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (04) :1830-1838
[8]  
KITO Y, 1984, T IEE JAPAN B, V104, P527
[9]   Stability analysis of a power system with superconducting fault current limiter installed [J].
Lee, S ;
Lee, C ;
Ko, TK ;
Hyun, O .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) :2098-2101
[10]  
LIOKA D, 2001, P INT ASS SCI TECHN, P329