Flexible biomedical microdevices with double-sided electrode arrangements for neural applications

被引:49
作者
Stieglitz, T [1 ]
机构
[1] Fraunhofer Inst Biomed Engn, Neural Prosthet Unit, D-66386 Sankt Ingbert, Germany
关键词
flexible substrate; biocompatibility; micromachining; polyimide; neural prostheses; double-sided electrodes;
D O I
10.1016/S0924-4247(01)00520-9
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Micromachined devices with substrate-integrated electrodes are the key components in implantable microsystems for recording of neural signals or electrical stimulation of nerves. So far, electrodes have been located on only one side of the microsystems. In this paper, a technology has been developed to fabricate multichannel microelectrodes that are located on the top side and the back side of a flexible device. The process technology for polyimide-based devices is described, prototypes of implantable microdevices with double-sided electrodes, called flexible nerve plates, have been fabricated. Results are discussed on scanning electron microscopy. cross-sections, and first electrochemical characterizations of the electrodes. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:203 / 211
页数:9
相关论文
共 24 条
[1]   A MICROMACHINED SILICON SIEVE ELECTRODE FOR NERVE REGENERATION APPLICATIONS [J].
AKIN, T ;
NAJAFI, K ;
SMOKE, RH ;
BRADLEY, RM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (04) :305-313
[2]   BATCH-FABRICATED THIN-FILM ELECTRODES FOR STIMULATION OF THE CENTRAL AUDITORY-SYSTEM [J].
ANDERSON, DJ ;
NAJAFI, K ;
TANGHE, SJ ;
EVANS, DA ;
LEVY, KL ;
HETKE, JF ;
XUE, XL ;
ZAPPIA, JJ ;
WISE, KD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (07) :693-704
[3]  
BOLZ A, 1991, P ANN INT C IEEE EMB, V13, P1474
[4]  
BOLZ A, 1995, BEDEUTUNG PHASENGREN
[5]  
CHANG LH, 1991, METALLIZATION PERFOR, V1596, P34
[6]   PERFORMANCE OF PLANAR MULTISITE MICROPROBES IN RECORDING EXTRACELLULAR SINGLE-UNIT INTRACORTICAL ACTIVITY [J].
DRAKE, KL ;
WISE, KD ;
FARRAYE, J ;
ANDERSON, DJ ;
BEMENT, SL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (09) :719-732
[7]   A flexible perforated microelectrode array probe for action potential recording in nerve and muscle tissues [J].
Gonzalez, C ;
Rodriguez, M .
JOURNAL OF NEUROSCIENCE METHODS, 1997, 72 (02) :189-195
[8]   Implantable bioelectronic interfaces for lost nerve functions [J].
Heiduschka, P ;
Thanos, S .
PROGRESS IN NEUROBIOLOGY, 1998, 55 (05) :433-461
[9]  
HETKE JF, 1990, SENSOR ACTUAT A-PHYS, V21, P999
[10]   SILICON-SUBSTRATE MICROELECTRODE ARRAYS FOR PARALLEL RECORDING OF NEURAL ACTIVITY IN PERIPHERAL AND CRANIAL NERVES [J].
KOVACS, GTA ;
STORMENT, CW ;
HALKSMILLER, M ;
BELCZYNSKI, CR ;
DELLASANTINA, CC ;
LEWIS, ER ;
MALUF, NI .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (06) :567-577