Immunomagnetic diffractometry for detection of diagnostic serum markers

被引:57
作者
Acharya, Ghanashyam [1 ]
Chang, Chun-Li [1 ]
Doorneweerd, Derek D. [1 ]
Vlashi, Erina [1 ]
Henne, Walter A. [1 ]
Hartmann, Lynn C. [3 ]
Low, Philip S. [1 ]
Savran, Cagri A. [1 ,2 ]
机构
[1] Purdue Univ, Birck Nanotechnol Ctr, Sch Elect & Comp Engn, Dept Chem,Sch Mech Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[3] Mayo Clin, Dept Oncol, Rochester, MN 55905 USA
关键词
D O I
10.1021/ja073094m
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We describe an integrated approach for detection of diagnostic markers using in situ assembled optical diffraction gratings in combination with immunomagnetic capture. Folate receptor (FR), a serum protein indicative of various cancers, was chosen as a model system to demonstrate the potential of the method. Magnetic beads coupled to FR antibody were used to capture FIR from serum. The FR-bound magnetic beads self-assembled onto microcontact-printed folate-coupled BSA (F-BSA) patterns to form diffraction gratings which served to detect FR by measuring the diffraction intensities caused by laser illumination. The FR-containing beads, upon binding to the F-BSA surface, served as intrinsic signal enhancement agents, circumventing the need for additional enzymatic signal amplification or fluorescent labeling steps. With this approach, a detection sensitivity of 700 fM (20 pg/mL) was achieved. The potential use of this approach in clinical diagnostics was demonstrated by measuring FR concentration in blood samples obtained from cancer patients.
引用
收藏
页码:15824 / 15829
页数:6
相关论文
共 39 条
  • [31] Rapid, universal method to isolate PCR-ready DNA using magnetic beads
    Rudi, K
    Kroken, M
    Dahlberg, OJ
    Deggerdal, A
    Jakobsen, KS
    Larsen, F
    [J]. BIOTECHNIQUES, 1997, 22 (03) : 506 - 511
  • [32] Safarikova M, 2001, MAGN ELECT SEP, V10, P223, DOI DOI 10.1155/2001/57434
  • [33] Schafer Frank, 2002, J Biomol Tech, V13, P131
  • [34] MEASUREMENT OF PROTEIN USING BICINCHONINIC ACID
    SMITH, PK
    KROHN, RI
    HERMANSON, GT
    MALLIA, AK
    GARTNER, FH
    PROVENZANO, MD
    FUJIMOTO, EK
    GOEKE, NM
    OLSON, BJ
    KLENK, DC
    [J]. ANALYTICAL BIOCHEMISTRY, 1985, 150 (01) : 76 - 85
  • [35] Soukka T, 2001, CLIN CHEM, V47, P1269
  • [36] Detection of prostate cancer and predicting progression: Current and future diagnostic markers
    Tricoli, JV
    Schoenfeldt, M
    Conley, BA
    [J]. CLINICAL CANCER RESEARCH, 2004, 10 (12) : 3943 - 3953
  • [37] Miniature analytical methods for medical diagnostics
    Walt, DR
    [J]. SCIENCE, 2005, 308 (5719) : 217 - 219
  • [38] Bioassay of prostate-specific antigen (PSA) using microcantilevers
    Wu, GH
    Datar, RH
    Hansen, KM
    Thundat, T
    Cote, RJ
    Majumdar, A
    [J]. NATURE BIOTECHNOLOGY, 2001, 19 (09) : 856 - 860
  • [39] Analysis and design of an interdigital cantilever as a displacement sensor
    Yaralioglu, GG
    Atalar, A
    Manalis, SR
    Quate, CF
    [J]. JOURNAL OF APPLIED PHYSICS, 1998, 83 (12) : 7405 - 7415