Esophagus sparing with IMRT in lung tumor irradiation: An EUD-based optimization technique

被引:36
作者
Chapet, O [1 ]
Thomas, E [1 ]
Kessler, ML [1 ]
Fraass, BA [1 ]
Ten Haken, RK [1 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2005年 / 63卷 / 01期
基金
美国国家卫生研究院;
关键词
optimization; EUD; IMRT; lung;
D O I
10.1016/j.ijrobp.2005.01.028
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study was to evaluate (1) the use of generalized equivalent uniform dose (gEUD) to optimize dose escalation of lung tumors when the esophagus overlaps the planning target volume (PTV) and (2) the potential benefit of further dose escalation in only the part of the PTV that does not overlap the esophagus. Methods and Materials: The treatment-planning computed tomography (CT) scans of patients with primary lung tumors located in different regions of the left and right lung were used for the optimization of beamlet intensity modulated radiation therapy (IMRT) plans. In all cases, the PTV overlapped part of the esophagus. The dose in the PTV was maximized according to 7 different primary cost functions: 2 plans that made use of mean dose (MD) (the reference plan, in which the 95% isodose surface covered the PTV and a second plan that had no constraint on the minimum isodose), 3 plans based on maximizing gEUD for the whole PTV with ever increasing assumptions for tumor aggressiveness, and 2 plans that used different gEUD values in 2 simultaneous, overlapping target volumes (the whole PTV and the PTV minus esophagus). Beam arrangements and NTCP-based costlets for the organs at risk (OARS) were kept identical to the original conformal plan for each case. Regardless of optimization method, the relative ranking of the resulting plans was evaluated in terms of the absence of cold spots within the PTV and the final gEUD computed for the whole PTV. Results: Because the MD-optimized plans lacked a constraint on minimum PTV coverage, they resulted in cold spots that affected approximately 5% of the PTV volume. When optimizing over the whole PTV volume, gEUD-optimized plans resulted in higher equivalent uniform PTV doses than did the reference plan while still maintaining normal-tissue constraints. However, only under the assumption of extremely aggressive tumors could cold spots in the PTV be avoided. Generally, high-level overall results are obtained when optimization in the whole PTV is also associated with a second simultaneous optimization in the PTV minus overlapping portions of the esophagus. Conclusions: Intensity modulated radiation therapy optimizations that utilize gEUD-based cost functions for the PTV and NTCP-based constraints for the OARS result in increased doses to large portions of the PTV in cases where the PTV overlaps the esophagus, while still maintaining (and confining to the overlap region) minimum dose coverage equivalent to the homogeneous PTV optimization cases. (c) 2005 Elsevier Inc.
引用
收藏
页码:179 / 187
页数:9
相关论文
共 47 条
[21]  
Lyman J. T., 1985, RADIAT RES, V8, P513
[22]   A CONVOLUTION METHOD OF CALCULATING DOSE FOR 15-MV X-RAYS [J].
MACKIE, TR ;
SCRIMGER, JW ;
BATTISTA, JJ .
MEDICAL PHYSICS, 1985, 12 (02) :188-196
[23]   Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer [J].
Mah, D ;
Hanley, J ;
Rosenzweig, KE ;
Yorke, E ;
Braban, L ;
Ling, CC ;
Leibel, SA ;
Mageras, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (04) :1175-1185
[24]  
Nguyen NP, 2002, ANTICANCER RES, V22, P3429
[25]   Reporting and analyzing dose distributions: A concept of equivalent uniform dose [J].
Niemierko, A .
MEDICAL PHYSICS, 1997, 24 (01) :103-110
[26]  
Niemierko A., 1999, MED PHYS, V26, P1100, DOI DOI 10.1118/1.598063
[27]   Dose escalation for non-small cell lung cancer using conformal radiation therapy [J].
Robertson, JM ;
TenHaken, RK ;
Hazuka, MB ;
Turrisi, AT ;
Martel, MK ;
Pu, AT ;
Littles, JF ;
Martinez, FJ ;
Francis, IR ;
Quint, LE ;
Lichter, AS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 37 (05) :1079-1085
[28]   High-dose conformal radiotherapy for treatment of Stage IIIA/IIIB non-small-cell lung cancer: Technical issues and results of a phase I/II trial [J].
Rosenman, JG ;
Halle, JS ;
Socinski, MA ;
Deschesne, K ;
Moore, DT ;
Johnson, H ;
Fraser, R ;
Morris, DE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (02) :348-356
[29]  
Rosenzweig KE, 2000, CANCER J, V6, P82
[30]   The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer [J].
Rosenzweig, KE ;
Hanley, J ;
Mah, D ;
Mageras, G ;
Hunt, M ;
Toner, S ;
Burman, C ;
Ling, CC ;
Mychalczak, B ;
Fuks, Z ;
Leibel, SA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (01) :81-87