Rapid concentration of bacteria using submicron magnetic anion exchangers for improving PCR-based multiplex pathogen detection

被引:18
作者
Yang, Kun [1 ]
Jenkins, Daniel M. [1 ]
Su, Wei Wen [1 ]
机构
[1] Univ Hawaii, Dept Mol Biosci & Bioengn, Honolulu, HI 96822 USA
关键词
Bacteria concentration; Ion exchange; Magnetic separation; Pathogen detection; Sample preparation; Nucleic acid amplification; ESCHERICHIA-COLI; NANOPARTICLES; SEPARATION; CAPTURE;
D O I
10.1016/j.mimet.2011.03.018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rapid concentration of bacterial targets from dilute solutions to improve subsequent PCR detection is investigated in this study. Submicron (average size 500 nm) superparamagnetic anion-exchangers (SiMAG-DEAE) were used successfully to concentrate target bacteria from very dilute solutions. A mass-balance model predicted that for Escherichia coli, the extent of cell concentrating increases almost linearly with increasing sample/SiMAG volume ratio up to about 2000, accompanied by only a slight decrease in the capture efficiency (<10%). Our experimental data generally support this analysis in that the SiMAG beads concentrated bacterial targets by two to three orders of magnitude using a sample/bead volume ratio of about 1000, and lowered the PCR detection limit to a level of 10(2) CFU/mL, from 10(4) to 10(5) CFU/mL without concentrating. Several target bacteria can be concentrated concurrently and detected via multiplex PCR, as illustrated using E. coli and Agrobacterium tumefaciens as model bacteria. Finally, concentration and detection of bacteria in fresh produce samples were demonstrated. The integration of submicron magnetic ion exchangers and PCR detection provides an appealing alternative to immunomagnetic separation/PCR in improving pathogen detection. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:69 / 77
页数:9
相关论文
共 19 条
[1]   Sample Preparation: The Forgotten Beginning [J].
Brehm-Stecher, Byron ;
Young, Crarles ;
Jaykus, Lee-Ann ;
Tortorello, Mary Lou .
JOURNAL OF FOOD PROTECTION, 2009, 72 (08) :1774-1789
[2]   Functional Magnetic Nanoparticles for Biodefense and Biological Threat Monitoring and Surveillance [J].
Bromberg, Lev ;
Raduyk, Svetlana ;
Hatton, T. Alan .
ANALYTICAL CHEMISTRY, 2009, 81 (14) :5637-5645
[3]   Solid-phase capture of pathogenic bacteria by using gangliosides and detection with real-time PCR [J].
Desai, Prerak T. ;
Walsh, Marie K. ;
Weimer, Bart C. .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2008, 74 (07) :2254-2258
[4]   Magnetic glyco-nanoparticles: A unique tool for rapid pathogen detection, decontamination, and strain differentiation [J].
El-Boubbou, Kheireddine ;
Gruden, Cyndee ;
Huang, Xuefei .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2007, 129 (44) :13392-+
[5]   Using biofunctional magnetic nanoparticles to capture vancomycin-resistant enterococci and other gram-positive bacteria at ultralow concentration [J].
Gu, HW ;
Ho, PL ;
Tsang, KWT ;
Wang, L ;
Xu, B .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (51) :15702-15703
[6]   UNIVERSAL PCR PRIMERS FOR DETECTION OF PHYTOPATHOGENIC AGROBACTERIUM STRAINS [J].
HAAS, JH ;
MOORE, LW ;
REAM, W ;
MANULIS, S .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1995, 61 (08) :2879-2884
[7]   PCR and blood culture for detection of Escherichia coli bacteremia in rats [J].
Heininger, A ;
Bider, M ;
Schmidt, S ;
Unertl, K ;
Botzenhart, K ;
Döring, G .
JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (08) :2479-2482
[8]  
HENEGARIU, 1997, BIOTECHNIQUES, V23, P504
[9]   Use of high-affinity cell wall-binding domains of bacteriophage endolysins for immobilization and separation of bacterial cells [J].
Kretzer, Jan W. ;
Lehmann, Rainer ;
Schmelcher, Mathias ;
Banz, Manuel ;
Kim, Kwang-Pyo ;
Korn, Corinna ;
Loessner, Martin J. .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2007, 73 (06) :1992-2000
[10]   Pathogen detection:: A perspective of traditional methods and biosensors [J].
Lazcka, Olivier ;
Del Campo, F. Javier ;
Munoz, F. Xavier .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (07) :1205-1217