Continuous glucose monitoring in the free-moving rat

被引:12
作者
Thomé-Duret, V
Aussedat, B
Reach, G
Gangnerau, MN
Lemonnier, F
Klein, JC
Zhang, Y
Hu, Y
Wilson, GS
机构
[1] Hotel Dieu, Serv Diabetol, INSERM, U341,Dept Diabetol, F-75004 Paris, France
[2] Ecole Mines, Fontainebleau, France
[3] Univ Kansas, Dept Chem, Lawrence, KS 66045 USA
来源
METABOLISM-CLINICAL AND EXPERIMENTAL | 1998年 / 47卷 / 07期
基金
美国国家卫生研究院;
关键词
D O I
10.1016/S0026-0495(98)90115-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this work was to set up an experimental model of glycemic fluctuations for assessing in the conscious freely moving rat, the performance of a continuous glucose-monitoring system, using a pocket-calculator-size electronic control unit and a miniaturized subcutaneous glucose sensor. The well-known triphasic glycemic pattern following streptozotocin injection (initial peak and secondary hypoglycemia preceding the establishment of permanent hyperglycemia) was used as a way to obtain spontaneous changes in blood glucose level over a wide concentration range. This report demonstrates that streptozotocin injection produced highly reproducible changes in the current generated by the sensor: an initial peak and a secondary nadir, during which blood sampling provided the evidence of hyperglycemia associated with immunoreactive hypoinsulinemia, and of hypoglycemia associated with hyperinsulinemia, respectively. This reproducible experimental model should be valuable for the assessment of a continuous glucose-monitoring system. Copyright (C) 1998 by W.B. Saunders Company.
引用
收藏
页码:799 / 803
页数:5
相关论文
共 15 条
  • [1] DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING
    BINDRA, DS
    ZHANG, YN
    WILSON, GS
    STERNBERG, R
    THEVENOT, DR
    MOATTI, D
    REACH, G
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (17) : 1692 - 1696
  • [2] BURCELIN R, 1995, DIABETOLOGIA, V38, P283, DOI 10.1007/BF00400632
  • [3] KAZUMI T, 1979, ENDOCRINOL JAPON, V26, P331
  • [4] KLEIN JC, 1995, HORM METAB RES, V27, P58
  • [5] TOWARDS CONTINUOUS GLUCOSE MONITORING - INVIVO EVALUATION OF A MINIATURIZED GLUCOSE SENSOR IMPLANTED FOR SEVERAL DAYS IN RAT SUBCUTANEOUS TISSUE
    MOATTISIRAT, D
    CAPRON, E
    POITOUT, V
    REACH, G
    BINDRA, DS
    ZHANG, Y
    WILSON, GS
    THEVENOT, DR
    [J]. DIABETOLOGIA, 1992, 35 (03) : 224 - 230
  • [6] MOATTISIRAT D, 1994, DIABETOLOGIA, V37, P610, DOI 10.1007/s001250050155
  • [7] EVALUATING INVITRO AND INVIVO, THE INTERFERENCE OF ASCORBATE AND ACETAMINOPHEN ON GLUCOSE DETECTION BY A NEEDLE-TYPE GLUCOSE SENSOR
    MOATTISIRAT, D
    VELHO, G
    REACH, G
    [J]. BIOSENSORS & BIOELECTRONICS, 1992, 7 (05) : 345 - 352
  • [8] PICKUP JC, 1991, BIOTECHNOLOGY INSULI, P126
  • [9] CALIBRATION IN DOGS OF A SUBCUTANEOUS MINIATURIZED GLUCOSE SENSOR USING A GLUCOSE METER FOR BLOOD-GLUCOSE DETERMINATION
    POITOUT, V
    MOATTISIRAT, D
    REACH, G
    [J]. BIOSENSORS & BIOELECTRONICS, 1992, 7 (08) : 587 - 592
  • [10] A GLUCOSE MONITORING-SYSTEM FOR ON LINE ESTIMATION IN MAN OF BLOOD-GLUCOSE CONCENTRATION USING A MINIATURIZED GLUCOSE SENSOR IMPLANTED IN THE SUBCUTANEOUS TISSUE AND A WEARABLE CONTROL UNIT
    POITOUT, V
    MOATTISIRAT, D
    REACH, G
    ZHANG, Y
    WILSON, GS
    LEMONNIER, F
    KLEIN, JC
    [J]. DIABETOLOGIA, 1993, 36 (07) : 658 - 663