We have previously described the use of a solid phase extraction (SPE) - capillary zone electrophoresis (CZE) - tandem mass spectrometry (MS/MS) system for protein analysis at the low femtomole to subfemtomole level. Here we describe the systematic optimization of a number of parameters which facilitate the use of the SPE-CZE-MS/MS system and further enhance its performance. Specifically, we describe a robust SPE cartridge design which can be assembled without the use of glue, the evaluation of procedures to chemically modify the inner wall of the fused-silica capillaries used in the system to improve separation and reproducibility, and the comparison of different reverse-phase (RP) resins used for the SPE cartridge. We also explored the effects of transient isotachophoresis with respect to system performance and compatibility with different fused-silica surface coatings, the RP resins used, and MS/MS. The enhanced performance of the optimized system is demonstrated by the analysis of calibrated tryptic digests of bovine serum albumin (BSA).
引用
收藏
页码:2338 / 2347
页数:10
相关论文
共 30 条
[1]   Instrumental requirements for nanoscale liquid chromatography [J].
Chervet, JP ;
Ursem, M ;
Salzmann, JB .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1507-1512
[2]   A MICROSCALE ELECTROSPRAY INTERFACE FOR ONLINE, CAPILLARY LIQUID-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY OF COMPLEX PEPTIDE MIXTURES [J].
DAVIS, MT ;
STAHL, DC ;
HEFTA, SA ;
LEE, TD .
ANALYTICAL CHEMISTRY, 1995, 67 (24) :4549-4556
[3]   DIRECT COUPLING OF OPEN-TUBULAR LIQUID-CHROMATOGRAPHY WITH MASS-SPECTROMETRY [J].
DEWIT, JSM ;
PARKER, CE ;
TOMER, KB ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1987, 59 (19) :2400-2404
[4]  
DRMANAC S, 1994, BIOTECHNIQUES, V17, P328
[5]   AN APPROACH TO CORRELATE TANDEM MASS-SPECTRAL DATA OF PEPTIDES WITH AMINO-ACID-SEQUENCES IN A PROTEIN DATABASE [J].
ENG, JK ;
MCCORMACK, AL ;
YATES, JR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (11) :976-989
[6]   Protein identification by capillary zone electrophoresis/microelectrospray ionization-tandem mass spectrometry at the subfemtomole level [J].
Figeys, D ;
vanOostveen, I ;
Ducret, A ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1996, 68 (11) :1822-1828
[7]   Identification of proteins by capillary electrophoresis tandem mass spectrometry - Evaluation of an on-line solid-phase extraction device [J].
Figeys, D ;
Ducret, A ;
Aebersold, R .
JOURNAL OF CHROMATOGRAPHY A, 1997, 763 (1-2) :295-306
[8]   High sensitivity identification of proteins by electrospray ionization tandem mass spectrometry: Initial comparison between an ion trap mass spectrometer and a triple quadrupole mass spectrometer [J].
Figeys, D ;
Aebersold, R .
ELECTROPHORESIS, 1997, 18 (3-4) :360-368
[9]   Protein identification by solid phase microextraction-capillary zone electrophoresis-microelectrospray-tandem mass spectrometry [J].
Figeys, D ;
Ducret, A ;
Yates, JR ;
Aebersold, R .
NATURE BIOTECHNOLOGY, 1996, 14 (11) :1579-1583
[10]   A microfabricated device for rapid protein identification by microelectrospray ion trap mass spectrometry [J].
Figeys, D ;
Ning, YB ;
Aebersold, R .
ANALYTICAL CHEMISTRY, 1997, 69 (16) :3153-3160