Derivation of electron and photon energy spectra from electron beam central axis depth dose curves

被引:36
作者
Deng, J [1 ]
Jiang, SB [1 ]
Pawlicki, T [1 ]
Li, JS [1 ]
Ma, CM [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
关键词
D O I
10.1088/0031-9155/46/5/308
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method for deriving the electron and photon energy spectra from electron beam central axis percentage depth dose (PDD) curves has been investigated. The PDD curves of 6, 12 and 20 MeV electron beams obtained from the Monte Carlo full phase space simulations of the Varian linear accelerator treatment head have been used to test the method. We have employed a 'random creep' algorithm to determine the energy spectra of electrons and photons in a clinical electron beam. The fitted electron and photon energy spectra have been compared with the corresponding spectra obtained from the Monte Carlo full phase space simulations. Our fitted energy spectra are in good agreement with the Monte Carlo simulated spectra in terms of peak location: peak width, amplitude and smoothness of the spectrum. In addition, the derived depth dose curves of head-generated photons agree well in both shape and amplitude with those calculated using the full phase space data. The central axis depth dose curves and dose profiles at various depths have been compared using an automated electron beam commissioning procedure. The comparison has demonstrated that our method is capable of deriving the energy spectra for the Varian accelerator electron beams investigated. We have implemented this method in the electron beam commissioning procedure for Monte Carlo electron beam dose calculations.
引用
收藏
页码:1429 / 1449
页数:21
相关论文
共 25 条
[1]   MONTE-CARLO TECHNIQUES IN MEDICAL RADIATION PHYSICS [J].
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07) :861-920
[2]  
Bielajew A., 1990, The Dosimetry of Ionizing Radiation, Volume, P427
[3]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[4]   RADIATION BEAM CHARACTERISTICS OF A 22 MEV MICROTRON [J].
BRAHME, A ;
SVENSSON, H .
ACTA RADIOLOGICA ONCOLOGY, 1979, 18 (03) :244-272
[5]   ELECTRON DOSE DISTRIBUTIONS IN EXPERIMENTAL PHANTOMS - A COMPARISON WITH 2D PENCIL BEAM CALCULATIONS [J].
CYGLER, J ;
BATTISTA, JJ ;
SCRIMGER, JW ;
MAH, E ;
ANTOLAK, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (09) :1073-1086
[6]   THE SPECTRAL DEPENDENCE OF ELECTRON CENTRAL-AXIS DEPTH-DOSE CURVES [J].
DEASY, JO ;
ALMOND, PR ;
MCELLISTREM, MT .
MEDICAL PHYSICS, 1994, 21 (09) :1369-1376
[7]   Photon beam characterization and modelling for Monte Carlo treatment planning [J].
Deng, J ;
Jiang, SB ;
Kapur, A ;
Li, JS ;
Pawlicki, T ;
Ma, CM .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02) :411-427
[8]   Electron spectra derived from depth dose distributions [J].
Faddegon, BA ;
Blevis, I .
MEDICAL PHYSICS, 2000, 27 (03) :514-526
[9]   ELECTRON-BEAM DOSE CALCULATIONS [J].
HOGSTROM, KR ;
MILLS, MD ;
ALMOND, PR .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (03) :445-459
[10]  
Jenkins T M., 1988, Monte Carlo Transport of Electrons and Photons