Photon beam characterization and modelling for Monte Carlo treatment planning

被引:112
作者
Deng, J [1 ]
Jiang, SB [1 ]
Kapur, A [1 ]
Li, JS [1 ]
Pawlicki, T [1 ]
Ma, CM [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
关键词
D O I
10.1088/0031-9155/45/2/311
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Photon beams of 4, 6 and 15 MV from Varian Clinac 2100C and 2300C/D accelerators were simulated using the EGS4/BEAM code system. The accelerators were modelled as a combination of component modules (CMs) consisting of a target, primary collimator, exit window, flattening filter, monitor chamber, secondary collimator, ring collimator, photon jaws and protection window. A full phase space file was scored directly above the upper photon jaws and analysed using beam data processing software, BEAMDP, to derive the beam characteristics, such as planar fluence, angular distribution, energy spectrum and the fractional contributions of each individual CM. A multiple-source model has been further developed to reconstruct the original phase space. Separate sources were created with accurate source intensity, energy, fluence and angular distributions for the target, primary collimator and flattening filter. Good agreement (within 2%) between the Monte Carlo calculations with the source model and those with the original phase space was achieved in the dose distributions for field sizes of 4cm x 4cm to 40cm x 40cm at source surface distances (SSDs) of 80-120 cm. The dose distributions in lung and bone heterogeneous phantoms have also been found to be in good agreement (within 2%) for 4, 6 and 15 MV photon beams for various field sizes between the Monte Carlo calculations with the source model and those with the original phase space.
引用
收藏
页码:411 / 427
页数:17
相关论文
共 36 条
[1]   COLLIMATOR SCATTER IN PHOTON THERAPY BEAMS [J].
AHNESJO, A .
MEDICAL PHYSICS, 1995, 22 (03) :267-278
[2]   ANALYTIC MODELING OF PHOTON SCATTER FROM FLATTENING FILTERS IN PHOTON THERAPY BEAMS [J].
AHNESJO, A .
MEDICAL PHYSICS, 1994, 21 (08) :1227-1235
[3]   APPLICATION OF THE CONVOLUTION METHOD FOR CALCULATION OF OUTPUT FACTORS FOR THERAPY PHOTON BEAMS [J].
AHNESJO, A ;
KNOOS, T ;
MONTELIUS, A .
MEDICAL PHYSICS, 1992, 19 (02) :295-301
[4]   MONTE-CARLO TECHNIQUES IN MEDICAL RADIATION PHYSICS [J].
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07) :861-920
[5]   STOPPING-POWER RATIOS AND THEIR UNCERTAINTIES FOR CLINICAL ELECTRON-BEAM DOSIMETRY [J].
ANDREO, P ;
FRANSSON, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (12) :1847-1861
[6]  
Bielajew A., 1990, The Dosimetry of Ionizing Radiation, Volume, P427
[7]  
BIELAJEW AF, 1987, NUCL INSTRUM METH B, V18, P165
[8]   MONTE-CARLO STUDY OF ACCELERATOR HEAD SCATTER [J].
CHANEY, EL ;
CULLIP, TJ ;
GABRIEL, TA .
MEDICAL PHYSICS, 1994, 21 (09) :1383-1390
[9]  
DEMARCO JJ, 1997, MED PHYS, V25, P1
[10]   AN ANALYTIC CALCULATION OF THE ENERGY FLUENCE SPECTRUM OF A LINEAR-ACCELERATOR [J].
DESOBRY, GE ;
BOYER, AL .
MEDICAL PHYSICS, 1994, 21 (12) :1943-1952