Optimal sizing method for stand-alone hybrid solar-wind system with LPSP technology by using genetic algorithm

被引:629
作者
Yang, Hongxing [1 ]
Zhou, Wei [1 ]
Lu, Lin [1 ]
Fang, Zhaohong [2 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
[2] Shandong Univ Architecture, Sch Thermal Engn, Jinan, Shandong, Peoples R China
关键词
hybrid solar-wind system; optimization; LPSP; annualized cost of system; genetic algorithm;
D O I
10.1016/j.solener.2007.08.005
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
System power reliability under varying weather conditions and the corresponding system cost are the two main concerns for designing hybrid solar-wind power generation systems. This paper recommends an optimal sizing method to optimize the configurations of a hybrid solar-wind system employing battery banks. Based on a genetic algorithm (GA), which has the ability to attain the global optimum with relative computational simplicity, one optimal sizing method was developed to calculate the optimum system configuration that can achieve the customers required loss of power supply probability (LPSP) with a minimum annualized cost of system (ACS). The decision variables included in the optimization process are the PV module number, wind turbine number, battery number, PV module slope angle and wind turbine installation height. The proposed method has been applied to the analysis of a hybrid system which supplies power for a telecommunication relay station, and good optimization performance has been found. Furthermore, the relationships between system power reliability and system configurations were also given. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:354 / 367
页数:14
相关论文
共 19 条
[1]  
[Anonymous], MAINTENANCE FREE BAT
[2]   An optimum dispatch strategy using set points for a photovoltaic (PV)-diesel-battery hybrid power system [J].
Ashari, M ;
Nayar, CV .
SOLAR ENERGY, 1999, 66 (01) :1-9
[3]   Methodology for optimally sizing the combination of a battery bank and PV array in a Wind/PV hybrid system [J].
Borowy, BS ;
Salameh, ZM .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1996, 11 (02) :367-373
[4]  
Duffie JA., 1980, Solar engineering of thermal processes
[5]  
Gipe P, 1995, WIND ENERGY COMES AG, P536
[6]   Dynamic battery model for photovoltaic applications [J].
Guasch, D ;
Silvestre, S .
PROGRESS IN PHOTOVOLTAICS, 2003, 11 (03) :193-206
[7]  
Holman J. P., 1992, HEAT TRANSFER
[8]   Generation unit sizing and cost analysis for stand-alone wind, photovoltaic, and hybrid wind/PV systems [J].
Kellogg, WD ;
Nehrir, MH ;
Venkataramanan, G ;
Gerez, V .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1998, 13 (01) :70-75
[9]   Methodology for optimal sizing of stand-alone photovoltaic/wind-generator systems using genetic algorithms [J].
Koutroulis, Eftichios ;
Kolokotsa, Dionissia ;
Potirakis, Antonis ;
Kalaitzakis, Kostas .
SOLAR ENERGY, 2006, 80 (09) :1072-1088
[10]  
Luis C., 2002, MODELING PHOTOVOLTAI