Determination of ozone removal rates by selected building products using the FLEC emission cell

被引:62
作者
Kleno, JG [1 ]
Clausen, PA [1 ]
Weschler, CJ [1 ]
Wolkoff, P [1 ]
机构
[1] Natl Inst Occupat Hlth, DK-2100 Copenhagen O, Denmark
关键词
D O I
10.1021/es000284n
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ozone removal by 16 aged (older than 1-120 months) but unused building products or materials was studied in a test system that included the field and laboratory emission cell (FLEC). The ozone removal was studied at 50 +/- 1 ppb ozone, a relative humidity of 50 +/- 5%, a temperature of 21 +/- 2 degreesC, and an air flow rate of 900 +/- 10 mL min(-1) through the FLEC lair velocity ca. 3 cm s(-1)). The ozone removal increased rapidly during the first 1-2 min and either remained at a constant level or decreased asymptotically to reach a steady state-like value. The ozone removal profiles for a given material showed good repeatability during replicate experiments. Ozone deposition velocities for the building products were calculated to be between 0.0007 cm s(-1) (lacquered ash) and 0.8 cm s(-1) (unpainted gypsum board).
引用
收藏
页码:2548 / 2553
页数:6
相关论文
共 23 条
[1]   REMOVAL OF REACTIVE GASES AT INDOOR SURFACES - COMBINING MASS-TRANSPORT AND SURFACE KINETICS [J].
CANORUIZ, JA ;
KONG, D ;
BALAS, RB ;
NAZAROFF, WW .
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1993, 27 (13) :2039-2050
[2]  
CASS GR, 1988, UNPUB PROTECTION WOR
[3]  
DOHAN JM, 1987, OZONE-SCI ENG, V9, P315
[4]  
KNUDSEN HN, 2000, P HEALTH BUILD 2000, V4, P217
[5]   The potential impact of ozone on materials in the UK [J].
Lee, DS ;
Holland, MR ;
Falla, N .
ATMOSPHERIC ENVIRONMENT, 1996, 30 (07) :1053-1065
[6]   Ozone decay rates in residences [J].
Lee, K ;
Vallarino, J ;
Dumyahn, T ;
Özkaynak, H ;
Spengler, JD .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1999, 49 (10) :1238-1244
[7]   Concentrations and decay rates of ozone in indoor air in dependence on building and surface materials [J].
Moriske, HJ ;
Ebert, G ;
Konieczny, L ;
Menk, G ;
Schöndube, M .
TOXICOLOGY LETTERS, 1998, 96-7 :319-323
[8]   Indoor air quality impacts of ventilation ducts: Ozone removal and emissions of volatile organic compounds [J].
Morrison, GC ;
Nazaroff, WW ;
Cano-Ruiz, JA ;
Hodgson, AT ;
Modera, MP .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1998, 48 (10) :941-952
[9]   The rate of ozone uptake on carpets: Experimental studies [J].
Morrison, GC ;
Nazaroff, WW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (23) :4963-4968
[10]   DECOMPOSITION RATES OF OZONE IN LIVING AREAS [J].
MUELLER, FX ;
LOEB, L ;
MAPES, WH .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1973, 7 (04) :342-346