Pericardial patch augmentation for reconstruction of incompetent bicuspid aortic valves

被引:28
作者
Doss, M
Moid, R
Wood, JP
Miskovic, A
Martens, S
Moritz, A
机构
[1] Univ Frankfurt, Dept Thorac & Cardiovasc Surg, D-60599 Frankfurt, Germany
[2] Univ Vienna, Dept Surg, Vienna, Austria
关键词
D O I
10.1016/j.athoracsur.2004.08.038
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose. Reoperation rates after repair of bicuspid aortic valves are higher than for mitral valve reconstruction. Secondary changes and small coaptation surface render repair unreliable. Satisfactory results have been reported for patch augmentation for tricuspid aortic valves. We have applied this technique for the repair of bicuspid aortic valves. Description. Our technique retains the bicuspid morphology of the incompetent aortic valve. A strip of glutaraldehyde-fixed pericardium is sutured to the free edge of the fused leaflet. A large coaptation surface is created, and competence of the bicuspid valve is achieved. Evaluation. Sixteen patients underwent reconstruction of their bicuspid aortic valves by pericardial patch augmentation. There were no intraoperative or postoperative deaths. The degree of aortic regurgitation was none to trivial for all patients at a mean follow-up of 3.1 +/- 3.4 months. Plartimetric effective orifice areas ranged above 2 cm(2). Mean aortic gradients were 8.2 +/- 4.8 mm. Hg, and the mean height of coaptation surface was 14.7 +/- 2.1 mm. Conclusions. The pericardial patch augmentation technique increases coaptation surface, and thus provides reliable early competence of reconstructed bicuspid aortic valves. (c) 2005 by The Society of Thoracic Surgeons.
引用
收藏
页码:304 / 308
页数:5
相关论文
共 14 条
[1]  
ALHALEES Z, 2004, 3 JOINT M ASS CARD S
[2]   Morphometric analysis of aortic media in patients with bicuspid and tricuspid aortic valve [J].
Bauer, M ;
Pasic, M ;
Meyer, R ;
Goetze, N ;
Bauer, U ;
Siniawski, H ;
Hetzer, R .
ANNALS OF THORACIC SURGERY, 2002, 74 (01) :58-62
[3]   Reduction aortoplasty for dilatation of the ascending aorta in patients with bicuspid aortic valve [J].
Bauer, M ;
Pasic, M ;
Schaffarzyk, R ;
Siniawski, H ;
Knollmann, F ;
Meyer, R ;
Hetzer, R .
ANNALS OF THORACIC SURGERY, 2002, 73 (03) :720-723
[4]   Ascending aortic aneurysm and dissection in young adults with bicuspid aortic valve: Implications for echocardiographic surveillance [J].
Burks, JM ;
Illes, RW ;
Keating, EC ;
Lubbe, WJ .
CLINICAL CARDIOLOGY, 1998, 21 (06) :439-443
[5]   Intermediate-term durability of bicuspid aortic valve repair for prolapsing leaflet [J].
Casselman, FP ;
Gillinov, AM ;
Akhrass, R ;
Kasirajana, V ;
Blackstone, EH ;
Cosgrove, DM .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 15 (03) :302-308
[6]   AORTIC-VALVE REPLACEMENT WITH AUTOLOGOUS PERICARDIUM - SURGICAL TECHNIQUE [J].
DURAN, CMG ;
GALLO, R ;
KUMAR, N .
JOURNAL OF CARDIAC SURGERY, 1995, 10 (01) :1-9
[7]   Treated bovine and autologous pericardium for aortic valve reconstruction [J].
Duran, CMG ;
Gometza, B ;
Shahid, M ;
Al-Halees, Z .
ANNALS OF THORACIC SURGERY, 1998, 66 (06) :S166-S169
[8]   FROM AORTIC CUSP EXTENSION TO VALVE-REPLACEMENT WITH STENTLESS PERICARDIUM [J].
DURAN, CMG ;
GOMETZA, B ;
KUMAR, N ;
GALLO, R ;
BJORNSTAD, K .
ANNALS OF THORACIC SURGERY, 1995, 60 (02) :S428-S432
[9]   AORTIC-VALVE REPLACEMENT WITH FREEHAND AUTOLOGOUS PERICARDIUM [J].
DURAN, CMG ;
GOMETZA, B ;
KUMAR, N ;
GALLO, R ;
MARTINDURAN, R .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 110 (02) :511-516
[10]   REPAIR OF INSUFFICIENT BICUSPID AORTIC VALVES [J].
FRASER, CD ;
WANG, N ;
MEE, RBB ;
LYTLE, BW ;
MCCARTHY, PM ;
SAPP, SK ;
ROSENKRANZ, ER ;
COSGROVE, DM .
ANNALS OF THORACIC SURGERY, 1994, 58 (02) :386-390