Performance of the YB66 soft X-ray monochromator crystal at the wiggler beamline of the UVSOR facility

被引:18
作者
Kinoshita, T [1 ]
Takata, Y
Matsukawa, T
Aritani, H
Matsuo, S
Yamamoto, T
Takahashi, M
Yoshida, H
Yoshida, T
Ufuktepe, Y
Nath, KG
Kimura, S
Kitajima, Y
机构
[1] Inst Mol Sci, Okazaki, Aichi 4448585, Japan
[2] Naruto Univ Educ, Dept Phys, Naruto 7728502, Japan
[3] Kyoto Univ, Dept Mol Engn, Kyoto 6068501, Japan
[4] Osaka Univ, Inst Sci & Ind Res, Ibaraki, Osaka 5670047, Japan
[5] Nagoya Univ, Sch Engn, Dept Appl Chem, Nagoya, Aichi 4648603, Japan
[6] Nagoya Univ, Ctr Integrated Sci & Engn, Div Energy Sci, Nagoya, Aichi 4648602, Japan
[7] Grad Univ Adv Studies, Dept Struct Mol Sci, Okazaki, Aichi 4448585, Japan
[8] KEK, High Energy Accelerator Res Org, Inst Mat Struct Sci, Tsukuba, Ibaraki 3050801, Japan
关键词
soft X-ray beamlines; YB66; crystals; double-crystal monochromators; wigglers;
D O I
10.1107/S0909049597017159
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Soft X-ray spectra have been measured using a pair of YB66(400) monochromator crystals at the double-crystal monochromator beamline BL7A of the UVSOR facility, where the wiggler radiation has a magnetic field of 4 T. Deformation of the YB66 crystal due to heat load from the synchrotron radiation is almost negligible. The photon flux is about 10(8) photons s(-1) (100 mA)(-1) in the energy region 1.2-2 keV and the energy resolution is 0.7 +/- 0.1 eV around hv = 1.5 keV. These results show that the YB66 crystal is suitable for use as a monochromator crystal. Its application to soft X-ray spectroscopy is discussed.
引用
收藏
页码:726 / 728
页数:3
相关论文
共 8 条
[1]   PERFORMANCE OF THE COOLING SYSTEM FOR THE SOFT-X-RAY DOUBLE-CRYSTAL MONOCHROMATOR AT THE PHOTON FACTORY [J].
FUNABASHI, M ;
NOMURA, M ;
KITAJIMA, Y ;
YOKOYAMA, T ;
OHTA, T ;
KURODA, H .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07) :1983-1986
[2]  
KINOSHITA T, 1998, IN PRESS J ELECTR SP
[3]   3D-]4F RESONANT PHOTOEMISSION IN RARE-EARTH SYSTEMS [J].
LAUBSCHAT, C ;
WESCHKE, E ;
KALKOWSKI, G ;
KAINDL, G .
PHYSICA SCRIPTA, 1990, 41 (01) :124-129
[4]   SOFT-X-RAY BEAMLINE BL7A AT THE UVSOR [J].
MURATA, T ;
MATSUKAWA, T ;
NAOE, S ;
HORIGOME, T ;
MATSUDO, O ;
WATANABE, M .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1309-1312
[5]   Construction and commissioning of a superconducting wiggler for the UVSOR storage ring [J].
Nakamura, E ;
Hama, H ;
Yamazaki, J ;
Kinoshita, T ;
Matsudo, O ;
Yonehara, H ;
Kasuga, T ;
Isoyama, G ;
Watanabe, M .
JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1996, 80 :421-424
[6]  
ROWEN M, 1993, SYNCHROTRON RAD NEWS, V6, P25
[7]   Nature of the 1385.6 and 1438 eV positive glitches in the transmission function of the YB66 soft-X-ray monochromator [J].
Tanaka, T ;
Aizawa, T ;
Rowen, M ;
Rek, ZU ;
Kitajima, Y ;
Higashi, I ;
Wong, J ;
Ishizawa, Y .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1997, 30 :87-91
[8]   YB-66 - A NEW SOFT-X-RAY MONOCHROMATOR FOR SYNCHROTRON RADIATION [J].
WONG, J ;
SHIMKAVEG, G ;
GOLDSTEIN, W ;
ECKART, M ;
TANAKA, T ;
REK, ZU ;
TOMPKINS, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (1-2) :243-249