Nonrandomized comparison of coronary stenting under intravascular ultrasound guidance of direct stenting without predilation versus conventional predilation with a semicompliant balloon versus predilation with a new scoring balloon

被引:68
作者
Costa, Jose de Ribamar, Jr.
Mintz, Gary S. [1 ]
Carlier, Stephane G.
Mehran, Roxana
Teirstein, Paul
Sano, Koichi
Liu, Xuebo
Lui, Joanna
Na, Yingbo
Castellanos, Celia
Biro, Sinan
Dani, Lockeshi
Rinker, Jason
Moussa, Issam
Dangas, George
Lansky, Alexandra J.
Kreps, Edward M.
Collins, Michael
Stone, Gregg W.
Moses, Jeffrey W.
Leon, Martin B.
机构
[1] Cardiovasc Res Fdn, New York, NY USA
[2] Columbia Univ, Med Ctr, New York, NY USA
关键词
D O I
10.1016/j.amjcard.2007.03.100
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study was conducted to determine the influence of lesion preparation using the AngioSculpt balloon on final stent expansion. Stent expansion remains an important predictor of restenosis and subacute thrombosis, even in the drug-eluting stent (DES) era. In these patients, the role of different predilation strategies has yet to be established. Two hundred ninety-nine consecutive de novo lesions treated with 1 > 2.5-mm DES (Cypher. or Taxus) under intravascular ultrasound guidance without postdilation, using 3 implantation strategies, were studied: (1) direct stenting without predilation (n = 145), (2) predilation with a conventional semi-compliant balloon (n = 117), and (3) predilation with the AngioSculpt balloon (n = 37). Stent expansion was defined as the ratio of intravascular. ultrasound-measured minimum stent diameter and minimum stent area to the manufacturer's predicted stent diameter and area. These ratios were larger after AngioSculpt predilation, and a greater percentage of stents had final minimum stent areas, > 5.0 mm(2). (another commonly accepted criterion of adequate DES expansion). Lesion morphology, stent and lesion length, and reference vessel size did not affect DES expansion. In-conclusion, in this observational, nonrandomized study, pretreatment with the AngioSculpt balloon enhanced stent expansion and minimized the difference between predicted and, achieved stent dimensions. (C) 2007 Elsevier Inc. All rights reserved.
引用
收藏
页码:812 / 817
页数:6
相关论文
共 14 条
[1]   Comparison of PRE-dilatation vs Direct Stenting In Coronary Treatment using the Medtronic AVE S670 Coronary Stent System (The PREDICT trial) [J].
Baim, DS ;
Flatley, M ;
Caputo, R ;
O'Shaughnessy, C ;
Low, R ;
Fanelli, C ;
Popma, J ;
Fitzgerald, P ;
Kuntz, R .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (12) :1364-1369
[2]   Meta-analysis of randomized trials of percutaneous transluminal coronary angioplasty versus atherectomy, cutting balloon atherotomy, or laser angioplasty [J].
Bittl, JA ;
Chew, DP ;
Topol, EJ ;
Kong, DF ;
Calif, RM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (06) :936-942
[3]   Intravascular ultrasonic assessment of Stent diameters derived from manufacturer's compliance charts [J].
Costa, JD ;
Mintz, GS ;
Carlier, SG ;
Costa, RA ;
Fujii, K ;
Sano, K ;
Kimura, M ;
Lui, J ;
Weisz, G ;
Moussa, I ;
Dangas, G ;
Mehran, R ;
Lansky, AJ ;
Kreps, EM ;
Collins, M ;
Stone, GW ;
Moses, JW ;
Leon, MB .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (01) :74-78
[4]   Intravascular ultrasound assessment of drug-eluting stent expansion [J].
Costa, Jose de Ribamar, Jr. ;
Mintz, Gary S. ;
Carlier, Stephane G. ;
Fujii, Kenichi ;
Sano, Koichi ;
Kimura, Masashi ;
Tanaka, Kaoru ;
Costa, Ricardo A. ;
Lui, Joanna ;
Na, Yingbo ;
Castellanos, Celia ;
Biro, Sinan ;
Moussa, Issam ;
Stone, Gregg W. ;
Moses, Jeffrey W. ;
Leon, Martin B. .
AMERICAN HEART JOURNAL, 2007, 153 (02) :297-303
[5]   Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting Stent implantation [J].
Fujii, K ;
Carlier, SG ;
Mintz, GS ;
Yang, YM ;
Moussa, I ;
Weisz, G ;
Dangas, G ;
Mehran, R ;
Lansky, AJ ;
Kreps, EM ;
Collins, M ;
Stone, GW ;
Lansky, AJ ;
Kreps, EM ;
Collins, M ;
Stone, GW ;
Moses, JW ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (07) :995-998
[6]   Treatment of calcified coronary lesions with Palmaz-Schatz stents - An intravascular ultrasound study [J].
Hoffmann, R ;
Mintz, GS ;
Popma, JJ ;
Satler, LF ;
Kent, KM ;
Pichard, AD ;
Leon, MB .
EUROPEAN HEART JOURNAL, 1998, 19 (08) :1224-1231
[7]   Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation [J].
Hong, Myeong-Ki ;
Mintz, Gary S. ;
Lee, Cheol Whan ;
Park, Duk-Woo ;
Choi, Bong-Ryong ;
Park, Kyoung-Ha ;
Kim, Young-Hak ;
Cheong, Sang-Sig ;
Song, Jae-Kwan ;
Kim, Jae-Joong ;
Park, Seong-Wook ;
Park, Seung-Jung .
EUROPEAN HEART JOURNAL, 2006, 27 (11) :1305-1310
[8]  
Katritsis Demosthenes G, 2006, J Invasive Cardiol, V18, P475
[9]   Cutting balloon angioplasty for the prevention of restenosis: Results of the cutting balloon global randomized trial [J].
Mauri, L ;
Bonan, R ;
Weiner, BH ;
Legrand, V ;
Bassand, JP ;
Popma, JJ ;
Niemyski, P ;
Prpic, R ;
Ho, KKL ;
Chauhan, MS ;
Cutlip, DE ;
Bertrand, OF ;
Kuntz, RE .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (10) :1079-1083
[10]   Stenting after optimal lesion debulking (SOLD) registry - Angiographic and clinical outcome [J].
Moussa, I ;
Moses, J ;
Di Mario, C ;
Busi, G ;
Reimers, B ;
Kobayashi, Y ;
Albiero, R ;
Ferraro, M ;
Colombo, A .
CIRCULATION, 1998, 98 (16) :1604-1609