Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography

被引:50
作者
Young, N
Dorsch, NWC
Kingston, RJ
Markson, G
McMahon, J
机构
[1] Westmead Hosp, Dept Radiol, Wentworthville, NSW 2145, Australia
[2] Westmead Hosp, Dept Neurosurg, Wentworthville, NSW 2145, Australia
关键词
spiral CT; intracranial aneurysm;
D O I
10.1007/s003300000523
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The goal of this study was to assess the usefulness of spiral CT angiography (CTA) with three- dimensional reconstructions in defining intracranial aneurysms, particularly around the Circle of Willis. Two hundred consecutive patients with angiographic and/or surgical correlation were studied between 1993 and 1998, with CTA performed on a GE HiSpeed unit and Windows workstation. The following clinical situations were evaluated: conventional CT suspicion of an aneurysm; follow-up of treated aneurysm remnants or of untreated aneurysms; subarachnoid haemorrhage (SAH) and negative angiography; family or past aneurysm history; and for improved definition of aneurysm anatomy. Spiral CTA detected 140 of 144 aneurysms, and an overall sensitivity of 97 %, including 30 of 32 aneurysms 3 mm or less in size. In 38 patients with SAH and negative angiography, CTA found six of the seven aneurysms finally diagnosed. There was no significant artefact in 17 of 23 patients (74 %) with clips. The specificity of CTA was 86 % with 8 false-positive cases. Spiral CTA is very useful in demonstrating intracranial aneurysms.
引用
收藏
页码:123 / 130
页数:8
相关论文
共 19 条
[1]   Experience with computed tomographic angiography for the detection of intracranial aneurysms in the setting of acute subarachnoid hemorrhage [J].
Wecht, DA ;
Awad, IA .
NEUROSURGERY, 1997, 41 (03) :528-528
[2]   TECHNICAL OPTIMIZATION OF SPIRAL CT FOR DEPICTION OF RENAL-ARTERY STENOSIS - IN-VITRO ANALYSIS [J].
BRINK, JA ;
LIM, JT ;
WANG, G ;
HEIKEN, JP ;
DEYOE, LA ;
VANNIER, MW .
RADIOLOGY, 1995, 194 (01) :157-163
[3]  
Brown JH, 1997, AM J NEURORADIOL, V18, P1794
[4]   EARLY EXPERIENCE WITH SPIRAL CT IN THE DIAGNOSIS OF INTRACRANIAL ANEURYSMS [J].
DORSCH, NWC ;
YOUNG, N ;
KINGSTON, RJ ;
COMPTON, JS .
NEUROSURGERY, 1995, 36 (01) :230-236
[5]  
HACKER RJ, 1983, INTRACRANIAL ANEURYS, P19
[6]  
Hope JKA, 1996, AM J NEURORADIOL, V17, P439
[7]   NATURAL-HISTORY OF UNRUPTURED INTRACRANIAL ANEURYSMS - A LONG-TERM FOLLOW-UP-STUDY [J].
JUVELA, S ;
PORRAS, M ;
HEISKANEN, O .
JOURNAL OF NEUROSURGERY, 1993, 79 (02) :174-182
[8]   Optimization of parameters for the detection of cerebral aneurysms: CT angiography of a model [J].
Kallmes, DF ;
Evans, AJ ;
Woodcock, RJ ;
Omary, RA ;
Dix, JE ;
McNulty, BC ;
Holder, CA ;
Dion, JE .
RADIOLOGY, 1996, 200 (02) :403-405
[9]   DETECTION AND ASSESSMENT OF INTRACRANIAL ANEURYSMS - VALUE OF CT ANGIOGRAPHY WITH SHADED-SURFACE DISPLAY [J].
LIANG, EY ;
CHAN, M ;
HSIANG, JHK ;
WALKDEN, SB ;
POON, WS ;
LAM, WWM ;
METREWELI, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (06) :1497-1502
[10]   Spiral CT angiography and surgical correlations in the evaluation of intracranial aneurysms [J].
Preda, L ;
Gaetani, P ;
Baena, RRY ;
Di Maggio, EM ;
La Fianza, A ;
Dore, R ;
Fulle, I ;
Solcia, M ;
Cecchini, A ;
Infuso, L ;
Campani, R .
EUROPEAN RADIOLOGY, 1998, 8 (05) :739-745