Aerosol size distribution in precipitation events in Leon, Spain

被引:48
作者
Castro, Amaya [1 ]
Alonso-Blanco, Elisabeth [1 ]
Gonzalez-Colino, Miguel [1 ]
Calvo, Ana I. [1 ]
Fernandez-Raga, Maria [1 ]
Fraile, Roberto [1 ]
机构
[1] Univ Leon, Dept Phys, IMARENAB, E-24071 Leon, Spain
关键词
Aerosol optical counter; Aerosol size distribution; Precipitation; Accumulation mode; Coarse mode; HYGROSCOPIC PROPERTIES; PARTICLES; URBAN; CLOSURE; RANGE;
D O I
10.1016/j.atmosres.2010.01.014
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Precipitation and continuous particle number size distributions have been measured using a passive cavity aerosol spectrometer probe PCASP-X, in an urban environment: the city of Leon, Spain. Five rain events have been analyzed in detail, none of which registered very intense precipitation, ranging from 2.5 mm to 14.7 mm, with a maximum rain intensity of 5.6 mm/h. The study focuses on the influence of precipitation in aerosol size distributions before, during and after a rain event. Washout effects have been observed during rain events with intensities of over 3.2 +/- 1.5 mm/h, resulting in a decrease of 20% in the number of particles detected, the decrease affecting large and small particles alike. However, if the rain intensity is about 0.6 mm/h or lower, the result is a considerable increase in the number of aerosols measured up to 89% more - with an increase in the number of particles smaller than 1.3 mu m and a decrease in the number of particles larger than 1.3 mu m. It may be the case that during very weak rain intensity the probe does not discriminate adequately between aerosols and small precipitating droplets or the extremely small droplets that remain in suspension in the atmosphere. In consequence, it will be argued that measurements taken during very weak rain events (with an intensity of less than 0.6 mm/h), such as drizzle or dense fog, should be treated separately or not be considered. The performance of the accumulation and coarse modes has also been studied, as well as the count median diameters (CMDs) before, during and after the rain event. (c) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:421 / 435
页数:15
相关论文
共 37 条
[21]   GROWTH LAWS FOR ATMOSPHERIC AEROSOL-PARTICLES - AN EXAMINATION OF THE BIMODALITY OF THE ACCUMULATION-MODE [J].
KERMINEN, VM ;
WEXLER, AS .
ATMOSPHERIC ENVIRONMENT, 1995, 29 (22) :3263-3275
[22]   The effects of particle chemical character and atmospheric processes on particle hygroscopic properties [J].
Kerminen, VM .
JOURNAL OF AEROSOL SCIENCE, 1997, 28 (01) :121-132
[23]   SIZE CALIBRATION CORRECTIONS FOR THE ACTIVE SCATTERING AEROSOL SPECTROMETER PROBE (ASASP-100X) [J].
KIM, YJ ;
BOATMAN, JF .
AEROSOL SCIENCE AND TECHNOLOGY, 1990, 12 (03) :665-672
[24]  
Lamb H.H., 1972, Geophys. Mem, V116
[25]  
Lide D.R., 2000, Handbook of Chemistry and Physics, V86th, P8
[26]   One-year data of submicron size modes of tropospheric background aerosol in Southern Finland [J].
Mäkelä, JM ;
Koponen, IK ;
Aalto, P ;
Kulmala, M .
JOURNAL OF AEROSOL SCIENCE, 2000, 31 (05) :595-611
[27]   Precipitation scavenging coefficient: influence of measured aerosol and raindrop size distributions [J].
Mircea, M ;
Stefan, S ;
Fuzzi, S .
ATMOSPHERIC ENVIRONMENT, 2000, 34 (29-30) :5169-5174
[28]   The hygroscopic properties of dicarboxylic and multifunctional acids: Measurements and UNIFAC predictions [J].
Peng, C ;
Chan, MN ;
Chan, CK .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (22) :4495-4501
[29]  
SLINN WGN, 1971, PHYS SIC, P75
[30]  
SUZUKI T, 1988, Tellus Series B Chemical and Physical Meteorology, V40, P42, DOI 10.1111/j.1600-0889.1988.tb00211.x