Four-dimensional cardiac imaging in living embryos via postacquisition synchronization of nongated slice sequences

被引:120
作者
Liebling, M
Forouhar, AS
Gharib, M
Fraser, SE
Dickinson, ME
机构
[1] CALTECH, Biol Imaging Ctr, Beckman Inst, Pasadena, CA 91125 USA
[2] CALTECH, Div Engn & Appl Sci, Pasadena, CA 91125 USA
关键词
confocal laser scanning microscopy; dynamic cardiac imaging; nongated synchronization; registration; wavelets;
D O I
10.1117/1.2061567
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Being able to acquire, visualize, and analyze 3D time series (4D data) from living embryos makes it possible to understand complex dynamic movements at early stages of embryonic development. Despite recent technological breakthroughs in 2D dynamic imaging, confocal microscopes remain quite slow at capturing optical sections at successive depths. However, when the studied motion is periodic-such as for a beating heart-a way to circumvent this problem is to acquire, successively, sets of 2D+time slice sequences at increasing depths over at least one time period and later rearrange them to recover a 3D+time sequence. In other imaging modalities at macroscopic scales, external gating signals, e.g., an electro-cardiogram, have been used to achieve proper synchronization. Since gating signals are either unavailable or cumbersome to acquire in microscopic organisms, we have developed a procedure to reconstruct volumes based solely on the information contained in the image sequences. The central part of the algorithm is a least-squares minimization of an objective criterion that depends on the similarity between the data from neighboring depths. Owing to a wavelet-based multiresolution approach, our method is robust to common confocal microscopy artifacts. We validate the procedure on both simulated data and in vivo measurements from living zebrafish embryos. (c) 2005 society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:10
相关论文
共 60 条
[1]   LAPLACIAN AND ORTHOGONAL WAVELET PYRAMID DECOMPOSITIONS IN COARSE-TO-FINE REGISTRATION [J].
ALLEN, RL ;
KAMANGAR, FA ;
STOKELY, EM .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1993, 41 (12) :3536-3541
[2]   LV volume quantification via spatiotemporal analysis of real-time 3-D echocardiography [J].
Angelini, ED ;
Laine, AF ;
Takuma, S ;
Holmes, JW ;
Homma, S .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (06) :457-469
[3]   Image coding using wavelet transform [J].
Antonini, Marc ;
Barlaud, Michel ;
Mathieu, Pierre ;
Daubechies, Ingrid .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1992, 1 (02) :205-220
[4]   PERFORMANCE OF OPTICAL-FLOW TECHNIQUES [J].
BARRON, JL ;
FLEET, DJ ;
BEAUCHEMIN, SS .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1994, 12 (01) :43-77
[5]  
Brent R. P., 1973, ALGORITHMS MINIMIZAT
[6]   Classification of nonexpansive symmetric extension transforms for multirate filter banks [J].
Brislawn, CM .
APPLIED AND COMPUTATIONAL HARMONIC ANALYSIS, 1996, 3 (04) :337-357
[7]   A SURVEY OF IMAGE REGISTRATION TECHNIQUES [J].
BROWN, LG .
COMPUTING SURVEYS, 1992, 24 (04) :325-376
[8]  
Carroll MJ, 1999, EUR J NUCL MED, V26, P1008
[9]  
Cox I. J., 1983, IMAGE VISION COMPUT, P52
[10]   Automated rectilinear self-gated cardiac cine imaging [J].
Crowe, ME ;
Larson, AC ;
Zhang, Q ;
Carr, J ;
White, RD ;
Li, DB ;
Simonetti, OP .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) :782-788