LV volume quantification via spatiotemporal analysis of real-time 3-D echocardiography

被引:87
作者
Angelini, ED
Laine, AF [1 ]
Takuma, S
Holmes, JW
Homma, S
机构
[1] Columbia Univ, Fu Fdn, Sch Engn & Appl Sci, Dept Biomed Engn, New York, NY 10027 USA
[2] Columbia Univ, Fu Fdn, Sch Engn & Appl Sci, Dept Biomed Engn & Radiol, New York, NY 10027 USA
[3] Columbia Univ, Coll Phys & Surg, Dept Med, Echocardio Labs,Columbia Presbyterian Med Ctr, New York, NY 10032 USA
关键词
echocardiography; LV volume; spaciotemporal analysis; speckle denoising;
D O I
10.1109/42.929612
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
This paper presents a method of four-dimensional (4-D) (3-D + Time) space-frequency analysis for directional denoising and enhancement of real-time three-dimensional (RT3D) ultrasound and quantitative measures in diagnostic cardiac ultrasound. Expansion of echocardiographic volumes is performed with complex exponential wavelet-like basis functions called brushlets, These functions offer good localization in time and frequency and decompose a signal into distinct patterns of oriented harmonics, which are invariant to intensity and contrast range. Deformable-model segmentation is carried out on denoised data after thresholding of transform coefficients, This process attenuates speckle noise while preserving cardiac structure location, The superiority of 4-D over 3-D analysis for decorrelating additive white noise and multiplicative speckle noise on a 4-D phantom volume expanding in time is demonstrated, Quantitative validation, computed for contours and volumes, is performed on in vitro balloon phantoms. Clinical applications of this spaciotemporal analysis tool are reported for six patient cases providing measures of left ventricular volumes and ejection fraction.
引用
收藏
页码:457 / 469
页数:13
相关论文
共 67 条
  • [1] Spatiotemporal directional analysis of 4D echocardiography
    Angelini, E
    Laine, A
    Takuma, S
    Homma, S
    [J]. WAVELET APPLICATIONS IN SIGNAL AND IMAGE PROCESSING VIII PTS 1 AND 2, 2000, 4119 : 605 - 614
  • [2] ANGELINI E, 1999, P 2 INT C MED IM COM, P430
  • [3] Multiple resolution Bayesian segmentation of ultrasound images
    Ashton, EA
    Parker, KJ
    [J]. ULTRASONIC IMAGING, 1995, 17 (04) : 291 - 304
  • [4] AUSHER P, 1996, WAVELETS TUTORIAL TH, V2, P237
  • [5] BERKNER K, 1998, 9801 CML TR RIC U CO
  • [6] Boukerroui D, 1999, LECT NOTES COMPUT SC, V1679, P516
  • [7] A multiple active contour model for cardiac boundary detection on echocardiographic sequences
    Chalana, V
    Linker, DT
    Haynor, DR
    Kim, YM
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (03) : 290 - 298
  • [8] CHANG SG, 1998, P INT C IM PROC CHIC
  • [9] Atomic decomposition by basis pursuit
    Chen, SSB
    Donoho, DL
    Saunders, MA
    [J]. SIAM JOURNAL ON SCIENTIFIC COMPUTING, 1998, 20 (01) : 33 - 61
  • [10] FINITE-ELEMENT METHODS FOR ACTIVE CONTOUR MODELS AND BALLOONS FOR 2-D AND 3-D IMAGES
    COHEN, LD
    COHEN, I
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1993, 15 (11) : 1131 - 1147