Assessment of breathlessness perception by Borg scale in asthmatic patients: Reproducibility and applicability to different stimuli

被引:16
作者
Chetta, A
Castagnaro, A
Foresi, A
Del Donno, M
Pisi, G
Malorgio, R
Olivieri, D
机构
[1] Univ Parma, Dept Resp Dis, I-43100 Parma, Italy
[2] Sesto S Giovanni Hosp, Resp Pathophysiol Unit, Milan, Italy
关键词
asthma; dyspnea; Borg scale;
D O I
10.1081/JAS-120018632
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
In asthmatics, the score of bronchoconstriction-associated breathlessness at 20% fall in forced expiratory volume at first second (FEV1) evaluated on a Borg scale (PS20) is a tool successfully used to measure the perception of symptoms. This prospective laboratory study evaluated the applicability Of PS20 to assess the breathlessness induced by ultrasonically nebulized distilled water (UNDW) and methacholine (M) and its reproducibility. Twenty-two mild and clinically stable asthmatic patients performed UNDW and M challenge tests. The PS20 was calculated by linear interpolation of the last two points of the perception/fall in FEV1 curve of the UNDW and M tests. The reproducibility Of PS20 M was assessed by repeating measurements on 2 separate days by 3 weeks. PS20 UNDW and PS20 M did not differ and were respectively 1.82 +/- 1.85 and 2.03 +/- 1.86. They were significantly related (r(s) = 0.63; p < 0.01) and the bias between PS20 UNDW and PS20 M was -0.21 with the limits of agreement ranging from -3.2 to 3.6. The intraclass correlation coefficient for repeated measurement Of PS20 M was 0.82; the bias between the two measurements was 0.2 with the limits of agreement ranging from -2.8 to 3.2. All patients had a measurable breathlessness perception degree on a Borg scale during both distilled water challenges and methacholine. Asthmatic patients with normal, exaggerated or poor breathlessness perception were also similar for both stimuli. In addition, PS20 showed a good reproducibility and this allows the serial evaluation of patient's breathlessness perception by this technique in clinical settings and in the physiology laboratory.
引用
收藏
页码:323 / 329
页数:7
相关论文
共 21 条
[1]  
[Anonymous], 1987, AM REV RESPIR DIS, V136, P225
[2]  
Armitage P, 1994, STAT METHODS MED RES, P273
[3]   Symptom perception and respiratory sensation in asthma [J].
Banzett, RB ;
Dempsey, JA ;
O'Donnell, DE ;
Wamboldt, MZ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 162 (03) :1178-1182
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   PERCEPTION SCORING OF INDUCED BRONCHOCONSTRICTION AS AN INDEX OF AWARENESS OF ASTHMA SYMPTOMS [J].
BOULET, LP ;
LEBLANC, P ;
TURCOTTE, H .
CHEST, 1994, 105 (05) :1430-1433
[6]   Influence of beclomethasone and salmeterol on the perception of methacholine-induced bronchoconstriction [J].
Boulet, LP ;
Turcotte, H ;
Cartier, A ;
Milot, J ;
Côté, J ;
Malo, JL ;
Laviolette, M .
CHEST, 1998, 114 (02) :373-379
[7]  
BURDON JGW, 1982, AM REV RESPIR DIS, V126, P825
[8]   Personality profiles and breathlessness perception in outpatients with different gradings of asthma [J].
Chetta, A ;
Gerra, G ;
Foresi, A ;
Zaimovic, A ;
Del Donno, M ;
Chittolini, B ;
Malorgio, R ;
Castagnaro, A ;
Olivieri, D .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 157 (01) :116-122
[9]   A comparison of the reproducibility and the sensitivity to change of visual analogue scales, Borg scales, and Likert scales in normal subjects during submaximal exercise [J].
Grant, S ;
Aitchison, T ;
Henderson, E ;
Christie, J ;
Zare, S ;
McMurray, J ;
Dargie, H .
CHEST, 1999, 116 (05) :1208-1217
[10]  
HUDGEL DW, 1982, AM REV RESPIR DIS, V126, P121