Timing of intra-aortic balloon pump support and 1-year survival

被引:28
作者
Ramnarine, IR
Grayson, AD [1 ]
Dihmis, WC
Mediratta, NK
Fabri, BM
Chalmers, JAC
机构
[1] Cardiothorac Ctr, Dept Clin Governance, Liverpool L14 3PE, Merseyside, England
[2] Cardiothorac Ctr, Dept Cardiothorac Surg, Liverpool, Merseyside, England
关键词
IABP support; CABG; valve surgery; mortality;
D O I
10.1016/j.ejcts.2005.02.001
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Objective: The relationship between the timing of intra-aortic balloon pump (IABP) support and surgical outcome remains a subject of debate. Peri-operative mechanical circulatory support is commenced either prophylactically or after increasing inotropic support has proved inadequate. This study evaluates the effect timing of IABP support on the 1-year survival of patients undergoing cardiac surgery. Methods: From April 1997 to September 2002, 7698 consecutive cardiac surgical procedures were performed. This included 5678 isolated coronary artery bypasses (CABGs), 1245 isolated valve procedures and 775 simultaneous CABG and valve procedures. IABP support was required in 237 patients (3.1%). Twenty-seven patients (0.35%) were classed as high-risk and received preoperative IABP support, 25 patients (0.32%) were haemodynamically compromised and required preoperative IABP support, 120 patients (1.56%) required intra-operative IABP support, and 65 patients (0.84%) required post-operative IABP support. Multiple variables were offered to a Cox proportional hazards model and significant predictors of 1-year survival were identified. These were used to risk adjust Kaplan-Meier survival curves. Results: 1-year follow-up was complete and 450 deaths (5.8%) were recorded. The significant independent predictors of increased mortality at 1-year (P < 0.05, HR = hazard ratio) were post-operative renal failure (HR = 3.5), increasing EuroSCORE (HR = 1.2), post-operative myocardial infarction (HR = 3.7), postoperative IABP (HR = 4.1) intra-operative IABP (HR = 2.8), post-operative stroke (HR = 2.5), increasing number of valves (HR = 1.6), ejection fraction < 30% (HR = 1.3) and triple-vesset disease (HR = 1.3). After risk-adjustment, 1-year survival for patients who required intra-operative IABP support was significantly greater than for those patients who required IABP support in the post-operative period. Conclusions: Patients who warrant IABP support in the post-operative setting have a significantly increased mortality at 1-year when compared to any other group. Therefore, earlier IABP support as part of surgical strategy may help to improve the outcome. (c) 2005 Elsevier B.V. AR rights reserved.
引用
收藏
页码:887 / 892
页数:6
相关论文
共 25 条
[1]
Vascular complications of the intraaortic balloon pump in patients undergoing open heart operations: 15-year experience [J].
Arafa, OE ;
Pedersen, TH ;
Svennevig, JL ;
Fosse, E ;
Geiran, OR .
ANNALS OF THORACIC SURGERY, 1999, 67 (03) :645-651
[2]
Intraaortic balloon pump in open heart operations: 10-year follow-up with risk analysis [J].
Arafa, OE ;
Pedersen, TH ;
Svennevig, JL ;
Fosse, E ;
Geiran, OR .
ANNALS OF THORACIC SURGERY, 1998, 65 (03) :741-747
[3]
The intraaortic balloon pump in cardiac surgery [J].
Baskett, RJF ;
Ghali, WA ;
Maitland, A ;
Hirsch, GM .
ANNALS OF THORACIC SURGERY, 2002, 74 (04) :1276-1287
[4]
Evaluation of preoperative intra-aortic balloon pump support in high risk coronary patients [J].
Christenson, JT ;
Simonet, F ;
Badel, P ;
Schmuziger, M .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 11 (06) :1097-1103
[5]
THE INTRAAORTIC BALLOON PUMP FOR POSTCARDIOTOMY HEART-FAILURE - EXPERIENCE WITH 169 INTRAAORTIC BALLOON PUMPS [J].
CHRISTENSON, JT ;
BUSWELL, L ;
VELEBIT, V ;
MAURICE, J ;
SIMONET, F ;
SCHMUZIGER, M .
THORACIC AND CARDIOVASCULAR SURGEON, 1995, 43 (03) :129-133
[6]
Trends in intraaortic balloon counterpulsation complications and outcomes in cardiac surgery [J].
Christenson, JT ;
Cohen, M ;
Ferguson, JJ ;
Freedman, RJ ;
Miller, MF ;
Ohman, M ;
Reddy, RC ;
Stone, GW ;
Urban, PM .
ANNALS OF THORACIC SURGERY, 2002, 74 (04) :1086-1090
[7]
Economic impact of preoperative intraaortic balloon pump therapy in high-risk coronary patients [J].
Christenson, JT ;
Simonet, F ;
Schmuziger, M .
ANNALS OF THORACIC SURGERY, 2000, 70 (02) :510-515
[8]
Intra-aortic balloon counterpulsation in US and non-US centres:: Results of the Benchmark® Registry [J].
Cohen, M ;
Urban, P ;
Christenson, JT ;
Joseph, DL ;
Freedman, RJ ;
Miller, MF ;
Ohman, EM ;
Reddy, RC ;
Stone, GW ;
Ferguson, JJ .
EUROPEAN HEART JOURNAL, 2003, 24 (19) :1763-1770
[9]
COX DR, 1972, J R STAT SOC B, V34, P187
[10]
Dunning Joel, 2003, Interact Cardiovasc Thorac Surg, V2, P416, DOI 10.1016/S1569-9293(03)00182-8