Defatted, gas-sterilised cortical bone allograft for posterior lumbar interbody vertebral fusion

被引:9
作者
Kakiuchi, M [1 ]
Ono, K [1 ]
机构
[1] Osaka Police Hosp, Dept Orthopaed Surg, Tennoji Ku, Osaka 543, Japan
关键词
D O I
10.1007/s002640050212
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In posterior lumbar interbody vertebral fusion operations, variously sized rectangular shaped, defatted, freeze-dried, gas-sterilised cortical bone allografts were used in combination with cancellous bone autografts from excised posterior elements. Single-level fusion, with or without internal fixation, was undertaken in 38 patients aged 50 years or less with disc herniation or a failed discectomy (the younger group) and in 33 women aged 60 years or more with degenerative spondylolisthesis (the older group). Of the various observable indicators of union, changes in the allograft-host interface alone proved to be of practical use. The incidence of nonunion in patients managed with pedicle screws, with a hook and rod system or without internal fixation was 0 of 8 patients; 1 of 14 patients; and 3 of 16 patients, respectively, in the younger group, and 0 of 11 patients; 0 of 8 patients; and 2 of 14 patients, respectively, in the older group. Of the six patients with nonunion, three had persistent low back pain and only two had mobility of the fused segment which was evident on lateral radiographs during flexion and extension. No patient had graft collapse. The decrease in the height of the intervertebral space, chiefly due to settlement of the allograft into the vertebral bodies, in the younger and older groups averaged 1.1 and 1.6 mm, respectively. We concluded that this simplified technique is mechanically sound and effective in maintaining the height of the intervertebral space. Even when the graft failed to unite, fibrous union could be obtained without graft collapse. Combination with a simple internal fixator; such as a compression rod facilitates bone union.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 10 条
[1]   COMPRESSION STRENGTH OF DONOR BONE FOR POSTERIOR LUMBAR INTERBODY FUSION [J].
BRANTIGAN, JW ;
CUNNINGHAM, BW ;
WARDEN, K ;
MCAFEE, PC ;
STEFFEE, AD .
SPINE, 1993, 18 (09) :1213-1221
[2]   Preparation of bank bone using defatting, freeze-drying and sterilisation with ethylene oxide gas .2. Clinical evaluation of its efficacy and safety [J].
Kakiuchi, M ;
Ono, K .
INTERNATIONAL ORTHOPAEDICS, 1996, 20 (03) :147-152
[3]   Preparation of bank bone using defatting, freeze-drying and sterilisation with ethylene oxide gas .1. Experimental evaluation of its efficacy and safety [J].
Kakiuchi, M ;
Ono, K ;
Nishimura, A ;
Shiokawa, H .
INTERNATIONAL ORTHOPAEDICS, 1996, 20 (03) :142-146
[4]  
KAKIUCHI M, 1993, LUMBAR FUSION STABIL, P354
[5]   THE TREATMENT OF OSTEOPOROTIC POSTTRAUMATIC VERTEBRAL COLLAPSE USING THE KANEDA DEVICE AND A BIOACTIVE CERAMIC VERTEBRAL PROSTHESIS [J].
KANEDA, K ;
ASANO, S ;
HASHIMOTO, T ;
SATOH, S ;
FUJIYA, M .
SPINE, 1992, 17 (08) :S295-S303
[6]  
KANEDA K, 1986, CLIN ORTHOP RELAT R, P159
[7]  
KOZAK JA, 1994, CLIN ORTHOP RELAT R, P45
[8]  
LIN PM, 1989, LUMBAR INTERBODY FUS, P55
[9]  
OHWADA T, 1993, LUMBAR FUSION STABIL, P208
[10]  
YAMAMOTO T, 1989, POSTERIOR LUMBAR INT, P177