Matrix-enhanced secondary ion mass spectrometry: the influence of MALDI matrices on molecular ion yields of thin organic films

被引:32
作者
Adriaensen, L
Vangaever, F
Lenaerts, J
Gijbels, R
机构
[1] Univ Antwerp, Dept Chem, MiTAC, B-2610 Antwerp, Belgium
[2] Agfa Gevaert NV, B-2640 Mortsel, Belgium
关键词
D O I
10.1002/rcm.1881
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work the effect in secondary ion mass spectrometry (SIMS) of several frequently used matrix-assisted laser desorption/ionisation (MALDI) matrices on the secondary ion intensities of low molecular weight (m/z 400-800) organic dyes and a pharmaceutical is tested. Matrix (10(-1) M) and analyte (10(-2) M) solutions were made in methanol. Mixtures with several concentration ratios were prepared from these solutions and spincoated on Si substrates prior to time-of-flight (TOF)SIMS analysis. In some cases the presence of the MALDI matrices caused a considerable increase in the positive secondary (protonated) molecular ion signals. Enhancements of a factor of 20 and more were recorded. Generally, of the matrices used, 2,5-dihydroxybenzoic acid and 2,4,6-trihydroxyacetophenone brought about the highest intensity increases. It was also shown that matrix-enhanced (ME-)SIMS is capable of lowering the detection limits for molecule ions. However, the enhancement effect is strongly influenced by the analyte/matrix combination and its concentration ratio. As a result, finding an optimal analyte/matrix mixture can be a very time-consuming process. Mostly, the presence of the matrices causes changes in the relative ion intensities in the TOFS-SIMS spectra. Compared to the spectra recorded from samples without matrices, only a few additional peaks, such as signals that originate directly from the applied matrix or adduct ions, are observed in the mass spectra. Sometimes molecule ions and some characteristic fragments at high m/z values, that cannot be recorded without matrix, do appear in the spectrum when a matrix is present. In the negative mode no enhancement effect is observed on applying the studied MALDI matrices. The results obtained from samples treated with MALDI matrices are also compared to SIMS results for the same samples after Ag and Au metallisation (MetA-SIMS). For three of the four tested compounds Au MetA-SIMS resulted in higher ion yields than ME-SIMS. For both techniques possible mechanisms that can account for the enhancement effect are proposed. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:1017 / 1024
页数:8
相关论文
共 35 条
[1]  
ADRIAENSEN L, 2005, IN PRESS J MASS SPEC
[2]  
ANDRIAENSEN L, 2004, ANAL CHEM, V76, P6777
[3]  
BRIGGS D, 1990, PRACTICAL SURFACE AN, V2, P303
[4]   MATRIX EFFECTS IN SECONDARY ION MASS-SPECTROMETRY [J].
BUSCH, KL ;
HSU, BH ;
XIE, YX ;
COOKS, RG .
ANALYTICAL CHEMISTRY, 1983, 55 (07) :1157-1160
[5]  
Choi BK, 2000, SURF INTERFACE ANAL, V29, P284, DOI 10.1002/(SICI)1096-9918(200004)29:4<284::AID-SIA741>3.0.CO
[6]  
2-R
[7]   Development and experimental application of a gold liquid metal ion source [J].
Davies, N ;
Weibel, DE ;
Blenkinsopp, P ;
Lockyer, N ;
Hill, R ;
Vickerman, JC .
APPLIED SURFACE SCIENCE, 2003, 203 :223-227
[8]   Sample metallization for performance improvement in desorption/ionization of kilodalton molecules: Quantitative evaluation, imaging secondary ion MS, and laser ablation [J].
Delcorte, A ;
Bour, J ;
Aubriet, F ;
Muller, JF ;
Bertrand, P .
ANALYTICAL CHEMISTRY, 2003, 75 (24) :6875-6885
[9]   Organic secondary ion mass spectrometry:: Sensitivity enhancement by gold deposition [J].
Delcorte, A ;
Médard, N ;
Bertrand, P .
ANALYTICAL CHEMISTRY, 2002, 74 (19) :4955-4968
[10]   Kiloelectronvolt particle-induced emission and fragmentation of polystyrene molecules adsorbed on silver: Insights from molecular dynamics [J].
Delcorte, A ;
Vanden Eynde, X ;
Bertrand, P ;
Vickerman, JC ;
Garrison, BJ .
JOURNAL OF PHYSICAL CHEMISTRY B, 2000, 104 (12) :2673-2691