摘要
Magnetic resonance (MR) imaging has recently been proposed for assessing osteoporosis and predicting fracture risks. However, accurate acquisition techniques and image analysis protocols for the determination of the trabecular bone structure are yet to be defined. The aim of this study was to assess the potential of projection reconstruction (PR) MR microscopy in the analysis of the three-dimensional (3-D) architecture of trabecular bone and in the prediction of its biomechanical properties. High-resolution 3-D PR images (41 x 41 x 82 mum(3) voxels) of 15 porcine trabecular bone explants were analyzed to determine the trabecular bone volume fraction (Vv), the mean trabecular thickness (Tb.Th), and the mean trabecular separation (Tb.Sp) using the method of directed secants. These parameters were then compared with those derived from 3-D conventional spin-echo microimages. In both cases, segmentation of the high-resolution images into bone and bone marrow was obtained using a spatial adaptive threshold. The contemporary inclusion of Vv, Tb.Th and 1/Tb.Sp in a multiple regression analysis significantly improved the prediction of Young's modulus (YM). The parameters derived from the PR spin-echo images were found to be stronger predictors of YM (R-2 = 0.94, p = 0.004) than those derived from conventional spin-echo images (R-2 = 0.79; p = 0.051). Our study indicates that projection reconstruction MR microscopy appears to be more accurate than the conventional Fourier transform method in the quantification of trabecular bone structure and in the prediction of its biomechanical properties. The proposed PR approach should be readily adaptable to the in vivo MRI studies of osteoporosis.
引用
收藏
页码:967 / 977
页数:11
相关论文
共 29 条
[1]  
BIRKENHAGERFRENKEL DH, 1988, BONE MINER, V4, P197
[2]   3D COMPUTED X-RAY TOMOGRAPHY OF HUMAN CANCELLOUS BONE AT 8 MU-M SPATIAL AND 10(-4) ENERGY RESOLUTION [J].
BONSE, U ;
BUSCH, F ;
GUNNEWIG, O ;
BECKMANN, F ;
PAHL, R ;
DELLING, G ;
HAHN, M ;
GRAEFF, W .
BONE AND MINERAL, 1994, 25 (01) :25-38
[3]   Evaluation of changes in trabecular bone architecture and mechanical properties of minipig vertebrae by three-dimensional magnetic resonance microimaging and finite element modeling [J].
Borah, B ;
Dufresne, TE ;
Cockman, MD ;
Gross, GJ ;
Sod, EW ;
Myers, WR ;
Combs, KS ;
Higgins, RE ;
Pierce, SA ;
Stevens, ML .
JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 (09) :1786-1797
[4]   PRINCIPLES OF COMPUTER-ASSISTED TOMOGRAPHY (CAT) IN RADIOGRAPHIC AND RADIOISOTOPIC IMAGING [J].
BROOKS, RA ;
DICHIRO, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (05) :689-732
[5]   CONTRAST-TO-NOISE RATIOS IN MAXIMUM INTENSITY PROJECTION IMAGES [J].
BROWN, DG ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :130-137
[6]  
Callaghan P.T., 1991, Principles of nuclear magnetic resonance microscopy, V1st
[7]   NUCLEAR MAGNETIC-RESONANCE MICROSCOPY WITH 4-MU-M RESOLUTION - THEORETICAL-STUDY AND EXPERIMENTAL RESULTS [J].
CHO, ZH ;
AHN, CB ;
JUH, SC ;
LEE, HK ;
JACOBS, RE ;
LEE, S ;
YI, JH ;
JO, JM .
MEDICAL PHYSICS, 1988, 15 (06) :815-824
[8]   CANCELLOUS BONE-STRUCTURE - ANALYSIS OF HIGH-RESOLUTION CT IMAGES WITH THE RUN-LENGTH METHOD [J].
DURAND, EP ;
RUEGSEGGER, P .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (01) :133-139
[9]   THE DIRECT EXAMINATION OF 3-DIMENSIONAL BONE ARCHITECTURE INVITRO BY COMPUTED-TOMOGRAPHY [J].
FELDKAMP, LA ;
GOLDSTEIN, SA ;
PARFITT, AM ;
JESION, G ;
KLEEREKOPER, M .
JOURNAL OF BONE AND MINERAL RESEARCH, 1989, 4 (01) :3-11
[10]   Magnetic resonance microscopy of morphological alterations in mouse trabecular bone structure under conditions of simulated microgravity [J].
Gardner, JR ;
Hess, CP ;
Webb, AG ;
Tsika, RW ;
Dawson, MJ ;
Gulani, V .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (06) :1122-1125