Magnetic resonance microscopy of morphological alterations in mouse trabecular bone structure under conditions of simulated microgravity

被引:12
作者
Gardner, JR
Hess, CP
Webb, AG
Tsika, RW
Dawson, MJ
Gulani, V
机构
[1] Univ Illinois, Dept Mol & Integrat Physiol, Urbana, IL 61801 USA
[2] Univ Illinois, Coll Med, Urbana, IL 61801 USA
[3] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL 61801 USA
[4] Univ Illinois, Beckman Inst, Urbana, IL 61801 USA
[5] Univ Missouri, Dept Vet Biomed Sci, Columbia, MO 65211 USA
[6] Univ Illinois, Biomed Magnet Resonance Lab, Urbana, IL 61801 USA
关键词
MR microscopy; hindlimb suspension; mouse tibial trabecular bone;
D O I
10.1002/mrm.1148
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This work describes the use of magnetic resonance (MR) microscopy to examine changes in tibial trabecular bone structure in mice following 28 days of hindlimb suspension, a model simulating the effects of microgravity in rodents. In this first MR study involving mice, analysis of 3D images showed that apparent bone volume fraction, trabecular number, and trabecular thickness were decreased, and apparent trabecular spacing increased, significantly (P < 0.05) in hindlimb-suspended mice compared to controls. These changes agreed well with light microcopy measurements from an independent study and also with actual spaceflight experiments with rats. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:1122 / 1125
页数:4
相关论文
共 20 条
[1]  
CHUNG HW, 1995, J BONE MINER RES, V10, P1452
[2]  
CHUNG HW, 1995, J BONE MINER RES, V10, P803
[3]   THE DIRECT EXAMINATION OF 3-DIMENSIONAL BONE ARCHITECTURE INVITRO BY COMPUTED-TOMOGRAPHY [J].
FELDKAMP, LA ;
GOLDSTEIN, SA ;
PARFITT, AM ;
JESION, G ;
KLEEREKOPER, M .
JOURNAL OF BONE AND MINERAL RESEARCH, 1989, 4 (01) :3-11
[4]   HIGH-RESOLUTION VARIABLE FLIP ANGLE 3D MR IMAGING OF TRABECULAR MICROSTRUCTURE INVIVO [J].
JARA, H ;
WEHRLI, FW ;
CHUNG, H ;
FORD, JC .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (04) :528-539
[5]   EFFECTS OF SPACEFLIGHT ON TRABECULAR BONE IN RATS [J].
JEE, WSS ;
WRONSKI, TJ ;
MOREY, ER ;
KIMMEL, DB .
AMERICAN JOURNAL OF PHYSIOLOGY, 1983, 244 (03) :R310-R314
[6]   MAGNETIC-RESONANCE MICROSCOPY IN RAT SKELETAL RESEARCH [J].
KAPADIA, RD ;
HIGH, WB ;
SOULLEVELD, HA ;
BERTOLINI, D ;
SARKAR, SK .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) :247-250
[7]  
Leach CS, 1977, BIOMEDICAL RESULTS S, P204
[8]   A comparative study of trabecular bone properties in the spine and femur using high resolution MRI and CT [J].
Link, TM ;
Majumdar, S ;
Lin, JC ;
Newitt, D ;
Augat, P ;
Ouyang, XL ;
Mathur, A ;
Genant, HK .
JOURNAL OF BONE AND MINERAL RESEARCH, 1998, 13 (01) :122-132
[9]   EVALUATION OF TECHNICAL FACTORS AFFECTING THE QUANTIFICATION OF TRABECULAR BONE-STRUCTURE USING MAGNETIC-RESONANCE-IMAGING [J].
MAJUMDAR, S ;
NEWITT, D ;
JERGAS, M ;
GIES, A ;
CHIU, E ;
OSMAN, D ;
KELTNER, J ;
KEYAK, J ;
GENANT, H .
BONE, 1995, 17 (04) :417-430
[10]   SPACEFLIGHT AND BONE TURNOVER - CORRELATION WITH A NEW RAT MODEL OF WEIGHTLESSNESS [J].
MOREY, ER .
BIOSCIENCE, 1979, 29 (03) :168-172