HIGH-RESOLUTION VARIABLE FLIP ANGLE 3D MR IMAGING OF TRABECULAR MICROSTRUCTURE INVIVO

被引:115
作者
JARA, H [1 ]
WEHRLI, FW [1 ]
CHUNG, H [1 ]
FORD, JC [1 ]
机构
[1] UNIV PENN,MED CTR,DEPT RADIOL,1 SILVERSTEIN,3400 SPRUCE ST,PHILADELPHIA,PA 19104
关键词
NMR MICROSCOPY; HIGH-RESOLUTION IMAGING; TRABECULAR STRUCTURE; SUSCEPTIBILITY EFFECTS;
D O I
10.1002/mrm.1910290415
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Two conceptually related variable-flip-angle 3D spin-echo pulse sequences were designed for imaging at voxel sizes of 2-5 X 10(-3) mm3 corresponding to pixel areas of less than 100 X 100 mum2 and section thicknesses on the order of 300-400 mum on a conventional 1.5 T MR imaging system equipped with 1 G/cm imaging field gradients, providing 12 sections in 10 min imaging time. The pulse sequences make use of the concept of restoring longitudinal magnetization inverted by the 180-degrees phase reversal pulse and are derivatives of pulse sequences previously dubbed ''FATE'' and ''RASEE.'' It is shown that even in the small-voxel regime (< 10(-2) mm3 voxel size) and at echo times on the order of 10 ms, gradient echo images are sensitive to intrinsic fields causing artifactual boundary effects, including signal loss from intravoxel phase scrambling and spatial mismapping. At this resolution the variable flip-angle spin-echo pulse sequences are demonstrated to be better suited for imaging magnetically heterogeneous systems such as trabecular bone microstructure in vivo. These pulse sequences are found to be substantially less sensitive to distortions from magnetic dipole fields occurring at the boundaries of two phases of different magnetic permeability.
引用
收藏
页码:528 / 539
页数:12
相关论文
共 33 条
[1]   OPTIMAL IMAGING STRATEGIES FOR 3-DIMENSIONAL NUCLEAR-MAGNETIC-RESONANCE MICROSCOPY [J].
AHN, CB ;
CHU, WC .
JOURNAL OF MAGNETIC RESONANCE, 1991, 94 (03) :455-470
[2]   LUNG PARENCHYMA - PROJECTION RECONSTRUCTION MR-IMAGING [J].
BERGIN, CJ ;
PAULY, JM ;
MACOVSKI, A .
RADIOLOGY, 1991, 179 (03) :777-781
[3]   INVIVO HIGH-RESOLUTION MR IMAGING OF THE SKIN IN A WHOLE-BODY SYSTEM AT 1.5 T [J].
BITTOUN, J ;
SAINTJALMES, H ;
QUERLEUX, BG ;
DARRASSE, L ;
JOLIVET, O ;
IDYPERETTI, I ;
WARTSKI, M ;
RICHARD, SB ;
LEVEQUE, JL .
RADIOLOGY, 1990, 176 (02) :457-460
[4]   RASEE - A RAPID SPIN-ECHO PULSE SEQUENCE [J].
BOGDAN, AR ;
JOSEPH, PM .
MAGNETIC RESONANCE IMAGING, 1990, 8 (01) :13-19
[5]   SIGNAL-TO-NOISE RATIO AND SECTION THICKNESS IN TWO-DIMENSIONAL VERSUS 3-DIMENSIONAL FOURIER-TRANSFORM MR IMAGING [J].
CARLSON, J ;
CROOKS, L ;
ORTENDAHL, D ;
KRAMER, DM ;
KAUFMAN, L .
RADIOLOGY, 1988, 166 (01) :266-270
[6]   NUCLEAR MAGNETIC-RESONANCE MICROSCOPY WITH 4-MU-M RESOLUTION - THEORETICAL-STUDY AND EXPERIMENTAL RESULTS [J].
CHO, ZH ;
AHN, CB ;
JUH, SC ;
LEE, HK ;
JACOBS, RE ;
LEE, S ;
YI, JH ;
JO, JM .
MEDICAL PHYSICS, 1988, 15 (06) :815-824
[7]  
CHUNG H, 1992, 11TH SOC MAGN RES ME
[8]  
EHRLI FW, 1990, FAST SCAN MAGNETIC R, P94
[9]  
ERICKSON SJ, 1988, AJR, V152, P1013
[10]   APPLICATION OF FOURIER TRANSFORM SPECTROSCOPY TO MAGNETIC RESONANCE [J].
ERNST, RR ;
ANDERSON, WA .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1966, 37 (01) :93-+