OPTIMAL IMAGING STRATEGIES FOR 3-DIMENSIONAL NUCLEAR-MAGNETIC-RESONANCE MICROSCOPY

被引:11
作者
AHN, CB [1 ]
CHU, WC [1 ]
机构
[1] KOREA ACAD IND TECHNOL,SEOUL 135080,SOUTH KOREA
来源
JOURNAL OF MAGNETIC RESONANCE | 1991年 / 94卷 / 03期
基金
美国国家卫生研究院;
关键词
D O I
10.1016/0022-2364(91)90132-D
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Imaging strategies optimized for high-field, high-resolution, three-dimensional nuclear magnetic resonance imaging and microscopy are investigated with a focus on the spin-diffusion process which predominantly determines image contrast as well as ultimate resolution and signal-to-noise ratio under strong gradient fields. Considerations include gradient-echo versus spin-echo techniques, real versus magnitude reconstructions, half-echo versus full-echo acquisitions, and low-diffusion-weighted imaging versus high-diffusion-weighted imaging. Experimental results with microscopic phantoms and a biological sample such as in vivo Xenopus laevis embryo are shown with a 7.0 T microscopy system. © 1991.
引用
收藏
页码:455 / 470
页数:16
相关论文
共 25 条
[1]   NUCLEAR-MAGNETIC-RESONANCE IMAGING OF A SINGLE CELL [J].
AGUAYO, JB ;
BLACKBAND, SJ ;
SCHOENIGER, J ;
MATTINGLY, MA ;
HINTERMANN, M .
NATURE, 1986, 322 (6075) :190-191
[2]   A NEW PHASE CORRECTION METHOD IN NMR IMAGING BASED ON AUTOCORRELATION AND HISTOGRAM ANALYSIS [J].
AHN, CB ;
CHO, ZH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1987, 6 (01) :32-36
[3]   ANALYSIS OF EDDY CURRENTS IN NUCLEAR-MAGNETIC-RESONANCE IMAGING [J].
AHN, CB ;
CHO, ZH .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (01) :149-163
[4]   THE EFFECTS OF RANDOM DIRECTIONAL DISTRIBUTED FLOW IN NUCLEAR-MAGNETIC-RESONANCE IMAGING [J].
AHN, CB ;
LEE, SY ;
NALCIOGLU, O ;
CHO, ZH .
MEDICAL PHYSICS, 1987, 14 (01) :43-48
[5]   AN IMPROVED NUCLEAR-MAGNETIC-RESONANCE DIFFUSION-COEFFICIENT IMAGING METHOD USING AN OPTIMIZED PULSE SEQUENCE [J].
AHN, CB ;
LEE, SY ;
NALCIOGLU, O ;
CHO, ZH .
MEDICAL PHYSICS, 1986, 13 (06) :789-793
[6]  
AHN CB, 1989, INVEST OPHTHALMOL VI, V30, P128
[7]  
AHN CB, 1989, MED PHYS, V16, P2
[8]   IMPROVED DETECTABILITY IN LOW SIGNAL-TO-NOISE RATIO MAGNETIC-RESONANCE IMAGES BY MEANS OF A PHASE-CORRECTED REAL RECONSTRUCTION [J].
BERNSTEIN, MA ;
THOMASSON, DM ;
PERMAN, WH .
MEDICAL PHYSICS, 1989, 16 (05) :813-817
[9]   RESOLUTION OF CELLULAR STRUCTURES BY NMR MICROSCOPY AT 11.7-T [J].
BOWTELL, RW ;
BROWN, GD ;
GLOVER, PM ;
MCJURY, M ;
MANSFIELD, P .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1990, 333 (1632) :457-467
[10]   SUSCEPTIBILITY-LIMITED RESOLUTION IN NUCLEAR-MAGNETIC-RESONANCE MICROSCOPY [J].
CALLAGHAN, PT .
JOURNAL OF MAGNETIC RESONANCE, 1990, 87 (02) :304-318