EVALUATION OF TECHNICAL FACTORS AFFECTING THE QUANTIFICATION OF TRABECULAR BONE-STRUCTURE USING MAGNETIC-RESONANCE-IMAGING

被引:150
作者
MAJUMDAR, S [1 ]
NEWITT, D [1 ]
JERGAS, M [1 ]
GIES, A [1 ]
CHIU, E [1 ]
OSMAN, D [1 ]
KELTNER, J [1 ]
KEYAK, J [1 ]
GENANT, H [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,MUSCULOSKELETAL SECT,SAN FRANCISCO,CA 94143
关键词
MAGNETIC RESONANCE IMAGING; MR; MICROSCOPY; TRABECULAR BONE; BONE ARCHITECTURE; FRACTAL DIMENSION; CONNECTIVITY;
D O I
10.1016/S8756-3282(95)00263-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
High resolution magnetic resonance (MR) techniques combined with standard techniques of stereology and texture analysis have been used to quantify trabecular structure. Using dried excised specimens from the tibia (n = 10) and radius (n = 2) we evaluate the impact of using volumetric gradient-echo (GE) and spin-echo (SE) MR imaging sequences, the relative importance of echo time in gradient-echo MR imaging, and the impact of different threshold values to segment the bone and bone marrow on the estimation of trabecular bone structure. We also investigate the inter-relationships between the different structural parameters derived from MR images, Images were obtained using fast gradient echo and spin-echo imaging sequences, with TE values ranging from 7 to 17 ms using 4.7 and 1.5 Tesla imaging systems. In-plane image resolution ranged from 128 to 156 mu m, and slice thickness ranged from 128 to 1000 mu m. We derived stereological measures such as the mean intercept length, trabecular width, fractional area of trabecular bone, trabecular number, and trabecular spacing, the fractal dimension as a texture-related parameter and the Euler number as a measure of connectivity from these images. We found that the mean intercept length as a function of angle traced an ellipse with the orientation of the principal axis of the ellipse, a measure of trabecular orientation, identical when measured from the spin echo or gradient-echo MR images, Absolute measures such as the fractional area, trabecular width, trabecular number, and fractal dimension as measured from gradient echo images were 28%, 30%, 1.3%, and 0.6% greater, respectively, than those calculated from spin-echo images, while the trabecular spacing was 14% less when calculated from gradient-echo images compared to spin-echo images. The structural parameters also depended on the echo time used to obtain the MR image. The choice of the threshold used to segment the high resolution images also affected the estimated structural parameters significantly, Our results indicate that MR may be used to visualize and quantify trabecular bone architecture; however, the different technical factors that could affect the appearance of MR images must be understood and considered in the data analysis and interpretation.
引用
收藏
页码:417 / 430
页数:14
相关论文
共 30 条
[1]   SIMULATION OF SUSCEPTIBILITY ARTIFACTS IN 2D AND 3D FOURIER-TRANSFORM SPIN-ECHO AND GRADIENT-ECHO MAGNETIC-RESONANCE-IMAGING [J].
BAKKER, CJG ;
BHAGWANDIEN, R ;
MOERLAND, MA ;
RAMOS, LMP .
MAGNETIC RESONANCE IMAGING, 1994, 12 (05) :767-774
[2]   SUSCEPTIBILITY ARTIFACTS IN 2DFT SPIN-ECHO AND GRADIENT-ECHO IMAGING - THE CYLINDER MODEL REVISITED [J].
BAKKER, CJG ;
BHAGWANDIEN, R ;
MOERLAND, MA ;
FUDERER, M .
MAGNETIC RESONANCE IMAGING, 1993, 11 (04) :539-548
[3]  
BENHAMOU CL, 1993, J BONE MINER RES S1S, V8, P263
[4]   NUMERICAL-ANALYSIS OF THE MAGNETIC-FIELD FOR ARBITRARY MAGNETIC-SUSCEPTIBILITY DISTRIBUTIONS IN 3D [J].
BHAGWANDIEN, R ;
MOERLAND, MA ;
BAKKER, CJG ;
BEERSMA, R ;
LAGENDIJK, JJW .
MAGNETIC RESONANCE IMAGING, 1994, 12 (01) :101-107
[5]   ON THE FRACTAL NATURE OF TRABECULAR STRUCTURE [J].
CHUNG, HW ;
CHU, CC ;
UNDERWEISER, M ;
WEHRLI, FW .
MEDICAL PHYSICS, 1994, 21 (10) :1535-1540
[6]   THE RELATIONSHIP BETWEEN THE ELASTICITY TENSOR AND THE FABRIC TENSOR [J].
COWIN, SC .
MECHANICS OF MATERIALS, 1985, 4 (02) :137-147
[7]   ON THE RELATIONSHIP BETWEEN THE ORTHOTROPIC YOUNGS MODULI AND FABRIC [J].
COWIN, SC ;
TURNER, CH .
JOURNAL OF BIOMECHANICS, 1992, 25 (12) :1493-1494
[8]  
DOYLE M, 1990, SPIE S LASER SCI APP, V1380, P227
[9]  
ENGELKE K, 1994, MAGNET RESON MED, V31, P384
[10]   THE DIRECT EXAMINATION OF 3-DIMENSIONAL BONE ARCHITECTURE INVITRO BY COMPUTED-TOMOGRAPHY [J].
FELDKAMP, LA ;
GOLDSTEIN, SA ;
PARFITT, AM ;
JESION, G ;
KLEEREKOPER, M .
JOURNAL OF BONE AND MINERAL RESEARCH, 1989, 4 (01) :3-11