Mid-infrared laser absorption spectroscopy in coiled hollow optical waveguides

被引:8
作者
Fetzer, GJ [1 ]
Pittner, AS [1 ]
Silkoff, PE [1 ]
机构
[1] Arete Associates, Tucson, AZ 85711 USA
来源
OPTICAL FIBERS AND SENSORS FOR MEDICAL APPLICATIONS III | 2003年 / 4957卷
关键词
inflammation; airways; asthma; nitric oxide; exhaled breath; laser spectroscopy;
D O I
10.1117/12.485398
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new nitric oxide (NO) sensor is intended for use in assessment of airway inflammation with applications in asthma diagnosis and management as well as in other health care applications involving inflammation in the gastrointestinal tract and the urogenital organs. The sensor was designed to measure trace quantities of NO in air using the combination of hollow optical waveguides and quantum cascade lasers. The primary application intended is analysis of exhaled breath. The unique marriage of the components and the novel design provides for rapid response to concentration changes while maintaining sensitive measurement capabilities. We achieved a lower detectable limit of 58.8 ppb of NO in N-2 with a 0-90% response time of 0.48 s. The QC laser was operated at room temperature in pulsed current mode near 5.4mum. The hollow waveguide used to make these measurements was 9m in length and the inside diameter was 1000mum. The waveguide was coiled with a 15cm radius of curvature and perforated on the interior walls of the coils to allow gas to flow into and out of the waveguide. The sensor can easily be converted to measure other gases in the mid-infrared by selecting a QC laser whose output is coincident with the absorption line of interest.
引用
收藏
页码:124 / 133
页数:10
相关论文
共 18 条
[1]   HOLLOW GLASS WAVE-GUIDES FOR BROAD-BAND INFRARED TRANSMISSION [J].
ABEL, T ;
HIRSCH, J ;
HARRINGTON, JA .
OPTICS LETTERS, 1994, 19 (14) :1034-1036
[2]  
ALVING K, 1993, EUR RESPIR J, V6, P1368
[3]   Exhaled nitric oxide correlates with airway hyperresponsiveness in steroid-naive patients with mild asthma [J].
Dupont, LJ ;
Rochette, F ;
Demedts, MG ;
Verleden, GM .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 157 (03) :894-898
[4]   QUANTUM CASCADE LASER [J].
FAIST, J ;
CAPASSO, F ;
SIVCO, DL ;
SIRTORI, C ;
HUTCHINSON, AL ;
CHO, AY .
SCIENCE, 1994, 264 (5158) :553-556
[5]   QUANTUM CASCADE LASER - AN INTERSUB-BAND SEMICONDUCTOR-LASER OPERATING ABOVE LIQUID-NITROGEN TEMPERATURE [J].
FAIST, J ;
CAPASSO, F ;
SIVCO, DL ;
SIRTORI, C ;
HUTCHINSON, AL ;
CHO, AY .
ELECTRONICS LETTERS, 1994, 30 (11) :865-866
[6]   Tunable diode laser absorption spectroscopy in coiled hollow optical waveguides [J].
Fetzer, GJ ;
Pittner, AS ;
Ryder, WL ;
Brown, DA .
APPLIED OPTICS, 2002, 41 (18) :3613-3621
[7]   MEASUREMENT OF MOLECULAR CONCENTRATIONS AND LINE PARAMETERS USING LINE-LOCKED 2ND HARMONIC SPECTROSCOPY WITH AN ALGAAS DIODE-LASER [J].
GOLDSTEIN, N ;
ADLERGOLDEN, S ;
LEE, J ;
BIEN, F .
APPLIED OPTICS, 1992, 31 (18) :3409-3415
[8]   ENDOGENOUS NITRIC-OXIDE IS PRESENT IN THE EXHALED AIR OF RABBITS, GUINEA-PIGS AND HUMANS [J].
GUSTAFSSON, LE ;
LEONE, AM ;
PERSSON, MG ;
WIKLUND, NP ;
MONCADA, S .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1991, 181 (02) :852-857
[9]   The predictive value of exhaled nitric oxide measurements in assessing changes in asthma control [J].
Jones, SL ;
Kittelson, J ;
Cowan, JO ;
Flannery, EM ;
Hancox, RJ ;
McLachlan, CR ;
Taylor, DR .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (05) :738-743
[10]   Exhaled and nasal nitric oxide measurements: Recommendations [J].
Kharitonov, S ;
Alving, K ;
Barnes, PJ .
EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (07) :1683-1693