How accurate is Whiteside's line as a reference axis in total knee arthroplasty?

被引:75
作者
Middleton, Fiona R.
Palmer, Simon H.
机构
[1] St Peters Hosp, Guildford, Surrey, England
[2] Worthing & Southlands NHS Trust, W Sussex, England
关键词
Whiteside's line; rotation;
D O I
10.1016/j.knee.2007.02.002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
There is an increasing focus on the precision with which prostheses in the knee are inserted with advent of computer assisted surgery. Much attention has been paid to the differences between this and conventional alignment jig techniques. Both techniques however rely on accurate identification of bony morphology and utilising this information to correctly orientate the prosthesis. Correct rotational alignment of the femoral prosthesis in total knee arthroplasty is important for correct patella tracking, patellofemoral joint contact forces, varus-valgus positioning in flexion, correct rotational alignment of the tibia in extension and the avoidance of anterior femoral notching. Whiteside's line is considered to be perpendicular to the epicondylar axis and therefore a reliable axis of reference. A cadaveric study was performed to assess the reliability and reproducibility of Whiteside's line in 50 cadaveric distal femora. Our results have shown that Whiteside's line is perpendicular to the epicondylar axis in the majority of cases (mean of 91 degrees). However the variation of values about the mean (range 80-102 degrees), and a SD of 4.7 degrees suggests that this should not be used alone as a rotational assessment guide. Rotation should ideally be checked against several axes to avoid errors in rotation positioning of the femoral prosthesis. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:204 / 207
页数:4
相关论文
共 36 条
[1]
AGAKI M, 2001, CLIN ORTHOP RELAT R, V388, P155
[2]
AGAKI M, 1999, CLIN ORTHOP RELAT R, V366, P155
[3]
ANOUCHI YS, 1993, CLIN ORTHOP RELAT R, V287, P170
[4]
FEMORAL ROTATIONAL ALIGNMENT, BASED ON THE ANTEROPOSTERIOR AXIS, IN TOTAL KNEE ARTHROPLASTY IN A VALGUS KNEE - A TECHNICAL NOTE [J].
ARIMA, J ;
WHITESIDE, LA ;
MCCARTHY, DS ;
WHITE, SE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (09) :1331-1334
[5]
BERGER RA, 1993, CLIN ORTHOP RELAT R, V286, P40
[6]
Computer-assisted knee arthroplasty versus a conventional jig-based technique -: A randomised, prospective trial [J].
Chauhan, SK ;
Scott, RG ;
Breidahl, W ;
Beaver, RJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (03) :372-377
[7]
DENNIS DA, 1992, AM J KNEE SURG, V5, P156
[8]
DORR LD, 1997, CLIN ORTHOP RELAT R, V205, P5
[9]
Three-dimensional morphology and kinematics of the distal part of the femur viewed in virtual reality - Part II [J].
Eckhoff, DG ;
Bach, JM ;
Spitzer, VM ;
Reinig, KD ;
Bagur, MM ;
Baldini, TH ;
Rubinstein, D ;
Humphries, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :97-104
[10]
Three-dimensional morphology of the distal part of the femur viewed in virtual reality [J].
Eckhoff, DG ;
Dwyer, TF ;
Bach, JM ;
Spitzer, VM ;
Reinig, KD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A :43-50