摘要
The viscoelastic response of bovine corneas was characterized using in vilro load-controlled uniaxial tension experiments. Specifically, two types of tests were employed: cycled ramp tests over a range of loading rates and creep tests over a range of hold stresses. Multiple replicates of each were used to quantify natural variability as well as mean trends. A preconditioning protocol was used to obtain a unique reference state before testing and to overcome the effects of non-physiological loading. A quasi-linear viscoelastic model incorporating a representation of the microstructure of the cornea was compared to the experimental results. For low stresses and moderate durations this model compares favorably, but overall the material displays non-linearities that cannot be represented within the quasi-linear framework. Published by Elsevier Ltd.
引用
收藏
页码:2367 / 2376
页数:10
相关论文
共 36 条
[1]
BIOMECHANICAL PROPERTIES OF KERATOCONUS AND NORMAL CORNEAS [J].
ANDREASSEN, TT ;
SIMONSEN, AH ;
OXLUND, H .
EXPERIMENTAL EYE RESEARCH, 1980, 31 (04) :435-441
[2]
Lamellar orientation in human cornea in relation to mechanical properties [J].
Boote, C ;
Dennis, S ;
Huang, YF ;
Quantock, AJ ;
Meek, KM .
JOURNAL OF STRUCTURAL BIOLOGY, 2005, 149 (01) :1-6
[3]
Collagen fibrils appear more closely packed in the prepupillary cornea: Optical and biomechanical implications [J].
Boote, C ;
Dennis, S ;
Newton, RH ;
Puri, H ;
Meek, KM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (07) :2941-2948
[4]
Constitutive laws for biomechanical modeling of refractive surgery [J].
Bryant, MR ;
McDonnell, PJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (04) :473-481
[5]
Stress relaxation preconditioning of porcine aortic valves [J].
Carew, EO ;
Garg, A ;
Barber, JE ;
Vesely, I .
ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (04) :563-572
[6]
COGAN D G, 1951, Trans Am Acad Ophthalmol Otolaryngol, V55, P329
[7]
The effect of strain rate on the viscoelastic response of aortic valve tissue: A direct-fit approach [J].
Doehring, TC ;
Carew, EO ;
Vesely, I .
ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (02) :223-232
[8]
PARAMETER-ESTIMATION USING THE QUASI-LINEAR VISCOELASTIC MODEL PROPOSED BY FUNG [J].
DORTMANS, LJMG ;
SAUREN, AAHJ ;
ROUSSEAU, EPM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1984, 106 (03) :198-203
[9]
Comparative study of corneal strip extensometry and inflation tests [J].
Elsheikh, A ;
Anderson, K .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2005, 2 (03) :177-185
[10]
Fung Y. C., 2013, BIOMECHANICS MECH PR