Stress relaxation preconditioning of porcine aortic valves

被引:38
作者
Carew, EO [1 ]
Garg, A [1 ]
Barber, JE [1 ]
Vesely, I [1 ]
机构
[1] Cleveland Clin Fdn, Dept Biomed Engn, Lerner Res Inst, Cleveland, OH 44195 USA
关键词
reference state; cyclic loading; cyclic stress relaxation; viscoelastic; porcine mitral valve; porcine aorta;
D O I
10.1023/B:ABME.0000019176.49650.19
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
In uniaxial tensile testing, load preconditioning is used to generate repeatable load/elongation curves and set a "reference state" for subsequent tensile tests. We have observed however, that for porcine aortic valve (PAV) tissues, preconditioning does not lead to repeatable stress relaxation curves. We thus investigated possible experimental protocols that could be used to generate repeatable load/elongation and stress relaxation curves. To quantify repeatability of stress relaxation, we compared normalized loads at the same time points from repeated stress relaxation curves and computed a repeatability ratio. We found that PAV specimens can generate repeatable stress relaxation curves (repeatability ratio >0.95) if they are subjected to at least five cycles of repeated load preconditioning and stress relaxation. We also found that a single cycle of loading/unloading prior to each stress relaxation phase is sufficient to generate repeatable stress relaxation curves. Stress relaxation preconditioning is therefore required to generate repeatable load/elongation and stress relaxation curves. It is expected that such curves will generate more accurate material constants for the characterization and modeling of PAV mechanics.
引用
收藏
页码:563 / 572
页数:10
相关论文
共 23 条
[1]
ANDERSON ER, 1999, 1 JOINT M BMES EMBS
[2]
AGE-RELATED COLLAGEN AND ELASTIN CONTENT OF HUMAN HEART VALVES [J].
BASHEY, RI ;
TORII, S ;
ANGRIST, A .
JOURNALS OF GERONTOLOGY, 1967, 22 (02) :203-&
[3]
ELASTIN CONTENT, CROSS-LINKS, AND MESSENGER-RNA IN NORMAL AND ANEURYSMAL HUMAN AORTA [J].
BAXTER, BT ;
MCGEE, GS ;
SHIVELY, VP ;
DRUMMOND, IAS ;
DIXIT, SN ;
YAMAUCHI, M ;
PEARCE, WH .
JOURNAL OF VASCULAR SURGERY, 1992, 16 (02) :192-200
[4]
Quasi-linear viscoelastic theory applied to internal shearing of porcine aortic valve leaflets [J].
Carew, EO ;
Talman, EA ;
Boughner, DR ;
Vesely, I .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (04) :386-392
[5]
Role of preconditioning and recovery time in repeated testing of aortic valve tissues: Validation through quasilinear viscoelastic theory [J].
Carew, EO ;
Barber, JE ;
Vesely, I .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (09) :1093-1100
[6]
Viscoelasticity of dynamically fixed bioprosthetic valves .2. Effect of glutaraldehyde concentration [J].
Duncan, AC ;
Boughner, D ;
Vesely, I .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 113 (02) :302-310
[7]
THE RETAINED ELASTICITY OF ELASTIN UNDER FIXATION AGENTS [J].
FUNG, YC ;
SOBIN, SS .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1981, 103 (02) :121-122
[8]
FUNG YC, 1993, BIOMECHANICS MECH PR, P260
[9]
HART ML, 1978, SCANNING ELECTRON MI, V2, P21
[10]
CONSTITUTIVE EQUATION FOR COLLAGEN FIBERS [J].
HAUT, RC ;
LITTLE, RW .
JOURNAL OF BIOMECHANICS, 1972, 5 (05) :423-&