Effect of ventilation distribution on aerosol bolus dispersion and recovery

被引:13
作者
Brown, JS
Gerrity, TR
Bennett, WD
机构
[1] Univ N Carolina, Ctr Environm Med & Lung Biol, Chapel Hill, NC 27599 USA
[2] US EPA, Natl Hlth & Environm Effects Res Lab, Clin Res Branch, Human Studies Div, Chapel Hill, NC 27599 USA
关键词
aerosol deposition; lung mechanics; obstructive lung disease;
D O I
10.1152/jappl.1998.85.6.2112
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
It has been speculated that convective ventilatory inhomogeneities are an important factor influencing aerosol bolus behavior in the compromised lung. Multiple-breath Xe-133 washout (MBWXe) is a commonly accepted test of ventilation distribution. By comparing aerosol bolus parameters to MBWXe in 9 healthy subjects and 14 cystic fibrosis patients with mild-to-moderate airway obstruction, we have attempted to discern the effect of altered ventilation distribution on aerosol bolus dispersion and recovery. Aerosol boluses (150-ml width) were delivered to the volumetric penetrations of 250 and 500 mi. Similar tidal volumes (similar to 1.25 liters) and flow rates (0.4 l/s) were used for aerosol bolus and MBWXe maneuvers. Associations between bolus parameters and ventilation distribution were only observed in the cystic fibrosis patients. We conclude that aerosol bolus dispersion and recovery are both influenced by convective ventilatory inhomogeneities induced by airway obstruction in these patients.
引用
收藏
页码:2112 / 2117
页数:6
相关论文
共 26 条
[1]   EFFECT OF CYSTIC-FIBROSIS ON INHALED AEROSOL BOLUSES [J].
ANDERSON, PJ ;
BLANCHARD, JD ;
BRAIN, JD ;
FELDMAN, HA ;
MCNAMARA, JJ ;
HEYDER, J .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 140 (05) :1317-1324
[2]   DETECTION OF SMALL AIRWAY DYSFUNCTION IN ASYMPTOMATIC SMOKERS USING AEROSOL BOLUS BEHAVIOR [J].
ANDERSON, PJ ;
HARDY, KG ;
GANN, LP ;
COLE, R ;
HILLER, FC .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 150 (04) :995-1001
[3]  
ANDERSON PJ, 1993, AM REV RESPIR DIS, V147, pA451
[4]   DETECTION OF EARLY LUNG IMPAIRMENT WITH AEROSOL BOLUS DISPERSION [J].
BRAND, P ;
TUCH, T ;
MANUWALD, O ;
BISCHOF, W ;
HEINRICH, J ;
WICHMANN, HE ;
BEINERT, T ;
HEYDER, J .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (10) :1830-1838
[5]  
BRAND P, 1995, J AEROSOL MED, V8, P123
[6]   CALCULATION OF EQUIVALENT AEROSOL-PARTICLE MOBILITY IN DIFFERENT MIXTURES OF GASES USED TO STUDY CONVECTIVE-TRANSPORT IN AIRWAYS [J].
BRIANT, JK .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1990, 3 (04) :221-232
[7]   DISPERSION OF AEROSOL BOLUSES IN THE HUMAN LUNG - DEPENDENCE ON LUNG-VOLUME, BOLUS VOLUME, AND GENDER [J].
BROWN, JS ;
GERRITY, TR ;
BENNETT, WD ;
KIM, CS ;
HOUSE, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 79 (05) :1787-1795
[8]  
BUIST AS, 1973, AM REV RESPIR DIS, V108, P1078
[9]   DOES THE SINGLE-BREATH N-2 TEST IDENTIFY THE SMOKER WHO WILL DEVELOP CHRONIC AIR-FLOW LIMITATION [J].
BUIST, AS ;
VOLLMER, WM ;
JOHNSON, LR ;
MCCAMANT, LE .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 137 (02) :293-301
[10]  
ENGEL LA, 1985, GAS MIXING DISTRIBUT, V25, P287