Evaluation of the pDR-1200 real-time aerosol monitor

被引:14
作者
Benton-Vitz, Kaila [1 ]
Volckens, John [1 ]
机构
[1] Colorado State Univ, Dept Environm & Radiol Hlth Sci, Ft Collins, CO 80523 USA
关键词
aspiration efficiency; light scattering; nephelometer; PM; response factor; transmission efficiency;
D O I
10.1080/15459620802009919
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
The objective of this research was to characterize the ability of the pDR-1200 real-time aerosol monitor to measure aerosols of varying size, composition, and origin. Particle aspiration and transmission efficiency was characterized at airflow rates of 2 L/min, 5 L/min, and 10 L/min in a wind tunnel in both static and orientation-averaged configurations. At 10 L/min, the particle cut point for 50% penetration of particles through the device (d50) was approximately 6 m, while at 2 L/min and 5 L/min the d50 was significantly larger, about 9 m (p = 0.01). There was no significant difference in particle penetration efficiency between facing-the-wind and orientation-averaged configurations (pavg = 0.66). The pDR-1200 response factor, which is defined as the ratio the time-averaged, monitor-reported concentration to a gravimetric filter concentration measured directly downstream of the sensing zone, was evaluated for four aerosol types: Arizona road dust, background ambient aerosol, environmental tobacco smoke, and diesel particulate matter. These aerosols, each of varying refractive index and particle size distribution, produced significant changes in the measured response factor (p 0.01). The pDR-1200 both overestimated and underestimated (up to a factor of 7) the gravimetrically determined aerosol concentration. These discrepancies further reinforce the need to calibrate the instrument in situ for each aerosol of interest. Inter-instrument variability was generally low for co-located monitors.
引用
收藏
页码:353 / 359
页数:7
相关论文
共 10 条
[1]
A survey of wind speeds in indoor workplaces [J].
Baldwin, PEJ ;
Maynard, AD .
ANNALS OF OCCUPATIONAL HYGIENE, 1998, 42 (05) :303-313
[2]
BARON P, 2001, AEROSOL MEASUREMENT, P419
[3]
Particle inhalability at low wind speeds [J].
Brown, JS .
INHALATION TOXICOLOGY, 2005, 17 (14) :831-837
[4]
Performance evaluation of the active-flow personal DataRAM PM2.5 mass monitor (Thermo Anderson pDR-1200) designed for continuous personal exposure measurements [J].
Chakrabarti, B ;
Fine, PM ;
Delfino, R ;
Sioutas, C .
ATMOSPHERIC ENVIRONMENT, 2004, 38 (20) :3329-3340
[5]
Aerosol light scattering measurements as a function of relative humidity [J].
Day, DE ;
Malm, WC ;
Kreidenweis, SM .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (05) :710-716
[6]
A DILUTION STACK SAMPLER FOR COLLECTION OF ORGANIC AEROSOL EMISSIONS - DESIGN, CHARACTERIZATION AND FIELD-TESTS [J].
HILDEMANN, LM ;
CASS, GR ;
MARKOWSKI, GR .
AEROSOL SCIENCE AND TECHNOLOGY, 1989, 10 (01) :193-204
[7]
HINDS WC, 1998, AEROSOL TECHNOLOGY P, P285
[8]
The orientation-averaged aspiration efficiency of IOM-like personal aerosol samplers mounted on bluff bodies [J].
Paik, SY ;
Vincent, JH .
ANNALS OF OCCUPATIONAL HYGIENE, 2004, 48 (01) :3-11
[9]
CORRELATIONS BETWEEN GRAVIMETRY AND LIGHT-SCATTERING PHOTOMETRY FOR ATMOSPHERIC AEROSOLS [J].
THOMAS, A ;
GEBHART, J .
ATMOSPHERIC ENVIRONMENT, 1994, 28 (05) :935-938
[10]
VINCENT JH, 1989, AEROSOL SAMPLING SCI, P93