Accumulation and fate of microorganisms and microspheres in biofilms formed in a pilot-scale water distribution system

被引:61
作者
Långmark, J
Storey, MV
Ashbolt, NJ
Stenström, TA
机构
[1] Swedish Inst Infect Dis Control, Dept Parasitol Mycol & Water Microbiol, SE-17182 Solna, Sweden
[2] Univ New S Wales, Ctr Water & Waste Technol, Sydney, NSW, Australia
关键词
D O I
10.1128/AEM.71.2.706-712.2005
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The accumulation and fate of model microbial "pathogens" within a drinking-water distribution system was investigated in naturally grown biofilms formed in a novel pilot-scale water distribution system provided with chlorinated and UV-treated water. Biofilms were exposed to 1-mum hydrophilic and hydrophobic microspheres, Salmonella bacteriophages 2813, and Legionella pneumophila bacteria, and their fate was monitored over a 38-day period. The accumulation of model pathogens was generally independent of the biofilm cell density and was shown to be dependent on particle surface properties, where hydrophilic spheres accumulated to a larger extent than hydrophobic ones. A higher accumulation of culturable legionellae was measured in the chlorinated system compared to the UV-treated system with increasing residence time. The fate of spheres and fluorescence in situ hybridization-positive legionellae was similar and independent of the primary disinfectant applied and water residence time. The more rapid loss of culturable legionellae compared to the fluorescence in situ hybridization-positive legionellae was attributed to a loss in culturability rather than physical desorption. Loss of bacteriophage 2813 plaque-forming ability together with erosion may have affected their fate within biofilms in the pilot-scale distribution system. The current study has demonstrated that desorption was one of the primary mechanisms affecting the loss of microspberes, legionellae, and bacteriophage from biofilms within a pilot-scale distribution system as well as disinfection and biological grazing. In general, two primary disinfection regimens (chlorination and UV treatment) were not shown to have a measurable impact on the accumulation and fate of model microbial pathogens within a water distribution system.
引用
收藏
页码:706 / 712
页数:7
相关论文
共 37 条
[31]  
Stoodley P, 1999, BIOTECHNOL BIOENG, V65, P83, DOI 10.1002/(SICI)1097-0290(19991005)65:1<83::AID-BIT10>3.3.CO
[32]  
2-2
[33]   Enteric virions and microbial biofilms - a secondary source of public health concern? [J].
Storey, MV ;
Ashbolt, NJ .
WATER SCIENCE AND TECHNOLOGY, 2003, 48 (03) :97-104
[34]   Persistence of two model enteric viruses (B40-8 and MS-2 bacteriophages) in water distribution pipe biofilms [J].
Storey, MV ;
Ashbolt, NJ .
WATER SCIENCE AND TECHNOLOGY, 2001, 43 (12) :133-138
[35]   Microbiological safety of drinking water [J].
Szewzyk, U ;
Szewzyk, R ;
Manz, W ;
Schleifer, KH .
ANNUAL REVIEW OF MICROBIOLOGY, 2000, 54 :81-127
[36]  
VANDERKOOIJ D, 1982, J AM WATER WORKS ASS, V74, P540
[37]   Heterogeneity in biofilms [J].
Wimpenny, J ;
Manz, W ;
Szewzyk, U .
FEMS MICROBIOLOGY REVIEWS, 2000, 24 (05) :661-671