Determination of alkylbenzyldimethylammonium chlorides in river water and sewage effluent by solid phase extraction and gas chromatography mass spectrometry

被引:57
作者
Ding, WH [1 ]
Liao, YH [1 ]
机构
[1] Natl Cent Univ, Dept Chem, Chungli 32054, Taiwan
关键词
D O I
10.1021/ac000655i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study presents a modified method to analyze alkylbenzyldimethylammonium chlorides (ABDACs) in river water and sewage effluent. The method involves mixed samples with linear alkylbenzenesulfonates (LAS) as a counterion to enhance the extraction of ABDAC residues from an RP-18 solid-phase cartridge by formation of hydrophobic ion-pair complexes. The ABDACs were then eluted with methanol-ethyl acetate (1:1, v/v) and formed to their corresponding alkyldimethylamines by the Hofmann degradation with potassium tert-butoxide. The alkyldimethylamines were then identified and quantitated by gas chromatograph/mass spectrometry (GC/MS). The results indicate that, in the presence of LAS, debenzylation of ABDACs occurs selectively at a temperature-higher than 90 degreesC to produce the corresponding nonionic alkyldimethylamines. The method proposed herein provides a high precision and sensitivity for ABDACs, to quantitation at less than or equal to0.1 mug/L in 500 mt of the water samples. The average recovery of ABDAC spiked water samples was 95% with relative standard deviations (RSD, n = 7) of 9%. The RSDs of three replicate environmental sample analyses ranged from 5 to 11%. Direct HPLC method was applied to evaluate the GC/MS method, and compatible results were observed.
引用
收藏
页码:36 / 40
页数:5
相关论文
共 25 条
[1]   GAS-LIQUID-CHROMATOGRAPHY OF STRAIGHT CHAIN HOMOLOGS OF ALKYLBENZYLDIMETHYLAMMONIUM COMPOUNDS [J].
ABIDI, SL .
JOURNAL OF CHROMATOGRAPHY, 1980, 200 (NOV) :216-220
[2]   RETENTION BEHAVIOR OF LONG-CHAIN QUATERNARY AMMONIUM HOMOLOGS AND RELATED NITROSO-ALKYLMETHYLAMINES [J].
ABIDI, SL .
JOURNAL OF CHROMATOGRAPHY, 1985, 324 (02) :209-230
[3]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF BENZALKONIUM IN PLASMA [J].
BLEAU, G ;
DESAULNIERS, M .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 487 (01) :221-227
[4]  
BOETHLING RS, 1992, HDB ENV CHEM, V3, P164
[5]   Occurrence and concentrations of aromatic surfactants and their degradation products in river waters of Taiwan [J].
Ding, WH ;
Tzing, SH ;
Lo, JH .
CHEMOSPHERE, 1999, 38 (11) :2597-2606
[6]   Analysis of linear alkylbenzenesulfonates in water samples by large-volume injection-port derivatization and gas chromatography-mass spectrometry [J].
Ding, WH ;
Chen, CT .
JOURNAL OF CHROMATOGRAPHY A, 1999, 857 (1-2) :359-364
[7]  
DJERASSI C, 1965, J AM CHEM SOC, V87, P5752, DOI 10.1021/ja00952a040
[8]   Determination of cationic surfactants by capillary electrophoresis [J].
Heinig, K ;
Vogt, C ;
Werner, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (04) :500-505
[9]   Analysis of benzalkonium chloride in the effluent from European hospitals by solid-phase extraction and high-performance liquid chromatography with post-column ion-pairing and fluorescence detection [J].
Kummerer, K ;
Eitel, A ;
Braun, U ;
Hubner, P ;
Daschner, F ;
Mascart, G ;
Milandri, M ;
Reinthaler, F ;
Verhoef, J .
JOURNAL OF CHROMATOGRAPHY A, 1997, 774 (1-2) :281-286
[10]   Separation of alkylbenzyl quaternary ammonium compounds by capillary zone electrophoresis - Effect of organic solvent in sample solution [J].
Lin, CE ;
Chiou, WC ;
Lin, WC .
JOURNAL OF CHROMATOGRAPHY A, 1996, 723 (01) :189-195