Numerical simulations of the second-order electrokinetic bias observed with the gated injection mode in chips

被引:9
作者
Blas, Maximilien
Delaunay, Nathalie
Ferrigno, Rosaria
Rocca, Jean-Louis
机构
[1] Univ Lyon 1, CNRS, Sci Analyt Lab, Villeurbanne, France
[2] Univ Lyon 1, Lab Elect Nanotechnol Capteurs, F-69622 Villeurbanne, France
关键词
electrokinetic injection; gated injection; separation chip;
D O I
10.1002/elps.200600692
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
It is well known that sample introduction via electrokinetic mode leads to a bias in conventional CE, which is proportional to the difference of electrophoretic mobilities between species. In electrophoretic separation chips using the gated injection mode, flow distribution at the crossjunction, which is linked to the electric field strength distribution during the loading step, induces an additional contribution to species discrimination. This second-order bias has a similar effect on quantitation like usual electrokinetic bias: the higher the analyte's apparent mobility, the larger the amount injected into the separation channel. The present paper assesses by numerical simulations the influence of several parameters, namely the injected amount, the electric field distribution, and the analyte-apparent Peclet number on this second-order bias.
引用
收藏
页码:2961 / 2970
页数:10
相关论文
共 35 条
[1]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[2]  
Bharadwaj R, 2002, ELECTROPHORESIS, V23, P2729, DOI 10.1002/1522-2683(200208)23:16<2729::AID-ELPS2729>3.0.CO
[3]  
2-I
[4]  
Bruin GJM, 2000, ELECTROPHORESIS, V21, P3931, DOI 10.1002/1522-2683(200012)21:18<3931::AID-ELPS3931>3.0.CO
[5]  
2-M
[6]   Conditions for similitude between the fluid velocity and electric field in electroosmotic flow [J].
Cummings, EB ;
Griffiths, SK ;
Nilson, RH ;
Paul, PH .
ANALYTICAL CHEMISTRY, 2000, 72 (11) :2526-2532
[7]  
Deshpande M, 2000, MESA MG, P339
[8]   HIGH-SPEED SEPARATION OF ANTISENSE OLIGONUCLEOTIDES ON A MICROMACHINED CAPILLARY ELECTROPHORESIS DEVICE [J].
EFFENHAUSER, CS ;
PAULUS, A ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1994, 66 (18) :2949-2953
[9]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[10]   Integrated microfluidic devices [J].
Erickson, D ;
Li, DQ .
ANALYTICA CHIMICA ACTA, 2004, 507 (01) :11-26