GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS

被引:474
作者
EFFENHAUSER, CS
MANZ, A
WIDMER, HM
机构
[1] Corporate Analytical Research, Ciba-Geigy Ltd.
关键词
D O I
10.1021/ac00067a015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Micromachined capillary electrophoresis systems with integrated sample injection have been fabricated on glass chips using standard photolithographic and etching techniques. The injector permits volume-defined electrokinetic sample injection without sample biasing. Utilization of short separation capillaries and high field strengths in combination with a small sample plug length results in both fast and efficient separations of fluorescein isothiocyanate- (FITC-) labeled amino acids. Analysis times range from a few seconds to a few tens of seconds with corresponding plate numbers of 5800-160 000, respectively. Plate heights down to 0.3 mum have been obtained using a separation length of 24 mm and an electric field of 1 kV/cm. As it turns out, a maximum separation efficiency has been reached, limited only by diffusion and the effects of both injection and detection. Automated repetitive sample injection and separation on a time scale of seconds is demonstrated and provides a route to quasi-continuous on-line monitoring of chemical species in a sensorlike fashion.
引用
收藏
页码:2637 / 2642
页数:6
相关论文
共 44 条
  • [1] [Anonymous], 2002, MODERN ELECTROCHEMIS, DOI DOI 10.1007/B114168
  • [2] BURGGRAF N, IN PRESS J HIGH RESO
  • [3] BURGGRAF N, IN PRESS ANAL METHOD
  • [4] AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY CAPILLARY ZONE ELECTROPHORESIS
    BUSHEY, MM
    JORGENSON, JW
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (10) : 978 - 984
  • [5] FLUORESCENCE DETECTOR CELL FOR USE IN AN INTEGRATED ELECTRICALLY DRIVEN SEPARATION SYSTEM
    DEBOKX, PK
    GILLISSEN, EEA
    VANDEWEIJER, P
    BEKKERS, MHJ
    VANBOMMEL, CHM
    JANSSEN, HG
    [J]. JOURNAL OF CHROMATOGRAPHY, 1992, 598 (01): : 115 - 121
  • [6] INFLUENCE OF ANALYTE PLUG WIDTH ON PLATE NUMBER IN CAPILLARY ELECTROPHORESIS
    DELINGER, SL
    DAVIS, JM
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (17) : 1947 - 1959
  • [7] PROBLEMS OF QUANTITATIVE INJECTION IN CAPILLARY ZONE ELECTROPHORESIS
    DOSE, EV
    GUIOCHON, G
    [J]. ANALYTICAL CHEMISTRY, 1992, 64 (02) : 123 - 128
  • [9] FILLIPINI C, 1991, J BIOTECHNOL, V18, P153
  • [10] A FLOW-INJECTION ANALYSIS SYSTEM FOR FERMENTATION MONITORING AND CONTROL
    GARN, M
    GISIN, M
    THOMMEN, C
    CEVEY, P
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1989, 34 (04) : 423 - 428