PROBLEMS OF QUANTITATIVE INJECTION IN CAPILLARY ZONE ELECTROPHORESIS

被引:51
作者
DOSE, EV
GUIOCHON, G
机构
[1] UNIV TENNESSEE,DEPT CHEM,KNOXVILLE,TN 37996
[2] OAK RIDGE NATL LAB,DIV ANALYT CHEM,OAK RIDGE,TN 37831
关键词
D O I
10.1021/ac00026a005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
CZE effective injection volumes are modified by two effects discussed in this article: diffusion and inadvertent hydrodynamic flow. Diffusion causes net flow into or out of the capillary whenever there exists a concentration gradient at the capillary inlet, and it is most important for small molecules, for short injection zones, and for slow injection sequences. Inadvertent hydrodynamic flow, most likely caused by a difference in levels of the liquids in the two reservoirs, is most important for liquid level differences of a few millimeters or more, for short injection zones, and for capillaries of short length and large inside diameter. Computer simulations of the first few millimeters of capillary length show how concentration profiles can develop rapidly.
引用
收藏
页码:123 / 128
页数:6
相关论文
共 18 条
  • [1] ELECTROPHORESIS - MATHEMATICAL-MODELING AND COMPUTER-SIMULATION
    BIER, M
    PALUSINSKI, OA
    MOSHER, RA
    SAVILLE, DA
    [J]. SCIENCE, 1983, 219 (4590) : 1281 - 1287
  • [2] SUBATTOMOLE AMINO-ACID ANALYSIS BY CAPILLARY ZONE ELECTROPHORESIS AND LASER-INDUCED FLUORESCENCE
    CHENG, YF
    DOVICHI, NJ
    [J]. SCIENCE, 1988, 242 (4878) : 562 - 564
  • [3] HIGH-RESOLUTION MODELING OF CAPILLARY ZONE ELECTROPHORESIS AND ISOTACHOPHORESIS
    DOSE, EV
    GUIOCHON, GA
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (11) : 1063 - 1072
  • [4] INTERNAL STANDARDIZATION TECHNIQUE FOR CAPILLARY ZONE ELECTROPHORESIS
    DOSE, EV
    GUIOCHON, GA
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (11) : 1154 - 1158
  • [5] HIGH-SPEED SEPARATIONS OF DNA SEQUENCING REACTIONS BY CAPILLARY ELECTROPHORESIS
    DROSSMAN, H
    LUCKEY, JA
    KOSTICHKA, AJ
    DCUNHA, J
    SMITH, LM
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (09) : 900 - 903
  • [6] CAPILLARY ELECTROPHORESIS
    GORDON, MJ
    HUANG, XH
    PENTONEY, SL
    ZARE, RN
    [J]. SCIENCE, 1988, 242 (4876) : 224 - 228
  • [7] INDIRECT FLUORIMETRIC DETECTION AND QUANTIFICATION IN CAPILLARY ZONE ELECTROPHORESIS OF INORGANIC ANIONS AND NUCLEOTIDES
    GROSS, L
    YEUNG, ES
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 480 : 169 - 178
  • [8] ZONE BROADENING DUE TO SAMPLE INJECTION IN CAPILLARY ZONE ELECTROPHORESIS
    GRUSHKA, E
    MCCORMICK, RM
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 471 : 421 - 428
  • [9] BIAS IN QUANTITATIVE CAPILLARY ZONE ELECTROPHORESIS CAUSED BY ELECTROKINETIC SAMPLE INJECTION
    HUANG, XH
    GORDON, MJ
    ZARE, RN
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (04) : 375 - 377
  • [10] QUANTITATIVE-ANALYSIS OF LOW-MOLECULAR WEIGHT CARBOXYLIC-ACIDS BY CAPILLARY ZONE ELECTROPHORESIS CONDUCTIVITY DETECTION
    HUANG, XH
    LUCKEY, JA
    GORDON, MJ
    ZARE, RN
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (07) : 766 - 770