Comparison of five days versus seven days of incubation for detection of positive blood cultures by the bactec 9240 system

被引:2
作者
Huang, AH
Yan, JJ
Wu, JJ
机构
[1] Natl Cheng Kung Univ, Coll Med, Dept Med Technol, Tainan 70101, Taiwan
[2] Natl Cheng Kung Univ, Ctr Med, Dept Pathol, Tainan 70428, Taiwan
关键词
D O I
10.1007/BF01708346
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
The specimen capacity of blood culture systems is determined by the length of time that blood cultures are incubated. Since the patient populations served by hospitals vary, individual laboratories should evaluate the relative cost and benefits of different testing regimens for their particular setting. To be cost-effective, the use of a 5-day rather than a 7-day protocol for the Bactec 9240 system (Becton Dickinson Diagnostic Instrument Systems, USA) has been recommended. To evaluate whether the shorter schedule would be appropriate at the Microbiology Laboratory at the National Cheng Kung University Medical Center in Tainan, Taiwan, the yield from 5 days versus 7 days of incubation was compared using a total of 9653 blood specimens collected from 1 April to 30 September 1997. Of the 1848 positive vials, 1822 (98.6%) were positive in the first 5 testing days; only 26 (1.4%) were positive on day 6 or 7. Only five of the latter vials were judged to contain clinically significant organisms: one Cryptococcus neoformans, one Candida albicans, one Enterobacter cloacae, one Klebsiella pneumoniae, and one Proteus mirabilis. Two vials contained organisms whose clinical significance was categorized as unknown, while 19 contained organisms that were considered contaminants. These data suggest that, for the laboratory studied, the 5-day protocol for the Bactec 9240 system is more cost-effective than the 7-day protocol and is adequate for detection of positive blood cultures.
引用
收藏
页码:637 / 641
页数:5
相关论文
共 13 条
[1]   DETECTION OF BACTEREMIA WITH THE BACTEC B-16 RESIN BLOOD CULTURE-MEDIUM [J].
DEGIROLAMI, PC ;
EICHELBERGER, K ;
SIEGEL, J .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1984, 81 (05) :643-646
[2]   DETECTION OF BACTEREMIA IN PATIENTS RECEIVING ANTI-MICROBIAL THERAPY - AN EVALUATION OF THE ANTI-MICROBIAL REMOVAL DEVICE AND B-16 MEDIUM [J].
DOERN, GV ;
GANTZ, NM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 18 (01) :43-48
[3]  
DUNNE WM, 1997, CUMITECH 1B BLOOD CU, V3, P1
[4]   Multicenter clinical comparison of Resin-containing bottles with standard aerobic and anaerobic bottles for culture of microorganisms from blood [J].
Lelievre, H ;
Gimenez, M ;
Vandenesch, F ;
Reinhardt, A ;
Lenhardt, D ;
Just, HM ;
Pau, M ;
Ausina, V ;
Etienne, J .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1997, 16 (09) :669-674
[5]   EVALUATION OF POSITIVE BLOOD CULTURES - GUIDELINES FOR EARLY DIFFERENTIATION OF CONTAMINATED FROM VALID POSITIVE CULTURES [J].
MACGREGOR, RR ;
BEATY, HN .
ARCHIVES OF INTERNAL MEDICINE, 1972, 130 (01) :84-+
[6]   DETECTION OF POSITIVE BLOOD CULTURES BY THE BACTEC NR660 - THE CLINICAL IMPORTANCE OF 5 VERSUS 7 DAYS OF TESTING [J].
MASTERSON, KC ;
MCGOWAN, JE .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1988, 90 (01) :91-94
[7]  
Merz William G., 1995, P709
[8]   Duration of incubation of fungal cultures [J].
Morris, AJ ;
Byrne, TC ;
Madden, JF ;
Reller, LB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (06) :1583-1585
[9]   MULTICENTER CLINICAL-EVALUATION OF A CONTINUOUS MONITORING BLOOD CULTURE SYSTEM USING FLUORESCENT-SENSOR TECHNOLOGY (BACTEC-9240) [J].
NOLTE, FS ;
WILLIAMS, JM ;
JERRIS, RC ;
MORELLO, JA ;
LEITCH, CD ;
MATUSHEK, S ;
SCHWABE, LD ;
DORIGAN, F ;
KOCKA, FE .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (03) :552-557
[10]   CONTROLLED CLINICAL COMPARISON OF ISOLATOR AND BACTEC-9240 AEROBIC-F RESIN BOTTLE FOR DETECTION OF BLOOD-STREAM INFECTIONS [J].
POHLMAN, JK ;
KIRKLEY, BA ;
EASLEY, KA ;
WASHINGTON, JA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (10) :2525-2529